Difference between revisions of "Saskatchewan P25 and Trunktrackers"
From The RadioReference Wiki
Line 141: | Line 141: | ||
|00 | |00 | ||
|06 | |06 | ||
− | | | + | |5 |
|- | |- | ||
|01 | |01 | ||
− | | | + | |07 |
|42 | |42 | ||
− | | | + | |5 |
|- | |- | ||
|02 | |02 | ||
− | | | + | |43 |
|72 | |72 | ||
− | | | + | |5 |
|- | |- | ||
|03 | |03 | ||
− | | | + | |73 |
+ | |144 | ||
+ | |5 | ||
+ | |- | ||
+ | |04 | ||
+ | |145 | ||
|168 | |168 | ||
− | | | + | |5 |
|- | |- | ||
− | | | + | |05 |
− | | | + | |169 |
|192 | |192 | ||
− | | | + | |5 |
|- | |- | ||
|} | |} | ||
− | |||
===Possible Firmware Issues=== | ===Possible Firmware Issues=== |
Revision as of 18:53, 11 October 2010
Contents
Trunktracker Information
- These M/A-COM P25ip Systems control channels use Multi-Block Messaging Operation for Explicit Group/Voice Channel Grants.
- All tower sites share the same system ID of HEX#00A/DEC#10 and the same WACN of HEX#0000A/DEC#10 and the same NAC of 10.
- These scanners will decode and trunktrack these systems, but older models may not;
The Radio Shack Pro-96/Pro-2096 can not decode the multi-block messages sent by the control channel so they may only trunk a single channel on a system. The BC250D and BC785D can not decode the 9600-baud rate control channel so it will not trunktrack these systems. The scanner must be able to operate in P25 9600 baud Explicit Mode.
Pro-96/2096 Trunking Information
- To trunktrack these systems the Pro-96/Pro-2096 must have custom extended tables programmed with Win96 software. These Radio Shack scanner models require a different set of custom trunking tables for every tower site in the system unless a site is used over again at another location in the Province. Channel #1 is 138.0150 and the last channel #100 is 139.5000. With this information the custom tables can be programmed for any tower site in the system.
- Tx Frequency Range 138-139.5000 MHz
- Rx Frequency Range 136.4150-137.9000 MHz
- Base = 138.000 in all cases
- Step = 5.0 in all cases
- Channel spacing is 15 KHz
Pro-96/2096 Custom Extended Tables
Site #001 Regina Downtown
Site | Name | Freqs | |||||
---|---|---|---|---|---|---|---|
10-005 (A-5) | Regina - SaskPower Head Office | 138.510000c | 138.675000c | 138.795000c | 139.035000c | 139.140000c | 139.245000c |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 102 | 5 |
01 | 103 | 135 | 5 |
02 | 136 | 159 | 5 |
03 | 160 | 207 | 5 |
04 | 208 | 228 | 5 |
05 | 229 | 249 | 5 |
Site #002 Pilot Butte
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-002 (A-2) | Alsask | 138.450000a | 138.555000a | 138.780000c | 139.275000a |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 105 | 5 |
01 | 106 | 153 | 5 |
02 | 154 | 174 | 5 |
03 | 175 | 198 | 5 |
Site #071 Fort Qu'Appelle
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-071 (A-47) | Fort Qu'Appelle | 138.240000a | 138.465000a | 139.095000c | 139.305000a |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 48 | 5 |
01 | 49 | 93 | 5 |
02 | 94 | 219 | 5 |
03 | 220 | 261 | 5 |
Site #081 Moose Jaw
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-181 (A-B5) | Pasqua | 138.030000c | 138.210000c | 138.360000c | 138.720000c |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 06 | 5 |
01 | 07 | 42 | 5 |
02 | 43 | 72 | 5 |
03 | 73 | 144 | 5 |
04 | 145 | 168 | 5 |
05 | 169 | 192 | 5 |
Possible Firmware Issues
- It appears that version 1.4 firmware is unable to trunktrack this system. Version 1.3 firmware seems to be required until/if RS issues any further fixes (thanks VE5WIL)
Refresh this page from the latest database entry