* 01 Generation | * 01 Generation | ||
− | * 02 Towers poles and fixtures | + | * 02 Towers, poles and fixtures |
* 03 Conductors and devices | * 03 Conductors and devices | ||
* 04 Transmision substations | * 04 Transmision substations | ||
− | * 09 Generation or | + | * 09 Generation or transmission, other |
==Distribution Substation Owned== | ==Distribution Substation Owned== | ||
Line 24: | Line 24: | ||
==Overhead Line Conductors and Devices, Distribution== | ==Overhead Line Conductors and Devices, Distribution== | ||
* 30 Line conductor | * 30 Line conductor | ||
− | * 31 | + | * 31 connector or clamp |
* 32 Splice or deadend | * 32 Splice or deadend | ||
* 33 Jumper | * 33 Jumper | ||
Line 43: | Line 43: | ||
* 51 Transformer fuse or breaker, refused or reset | * 51 Transformer fuse or breaker, refused or reset | ||
* 52 transformer lightning arrestor | * 52 transformer lightning arrestor | ||
− | == Secondaries and Services== | + | ==Secondaries and Services== |
* 60 Secondary or Service conductor | * 60 Secondary or Service conductor | ||
* 61 Meter or meter loop | * 61 Meter or meter loop | ||
Line 61: | Line 61: | ||
==Major Storm Disaster== | ==Major Storm Disaster== | ||
* 20 Storm damage | * 20 Storm damage | ||
− | ==Equipment or | + | ==Equipment or Installation== |
* 30 Material or equipment fault | * 30 Material or equipment fault | ||
− | * 31 | + | * 31 Installation fault |
* 32 Conductor sag or clearance not adequate | * 32 Conductor sag or clearance not adequate | ||
* 39 Faulty material or installation, other | * 39 Faulty material or installation, other |
Revision as of 17:56, 4 February 2010
Equipment or Material Responsible for Interruption
Power Supplier
- 00 Power supplier
Generation or Transmission If Owned
- 01 Generation
- 02 Towers, poles and fixtures
- 03 Conductors and devices
- 04 Transmision substations
- 09 Generation or transmission, other
Distribution Substation Owned
- 10 Transformer
- 11 Voltage regulator or breaker
- 12 Lightning arrester or switch
- 13 Source side fuse
- 19 Other
Poles and Fixtures,Distrubution
- 20 Pole
- 21 Crossarm or crossarm brace
- 22 Anchor or guy
- 29 Other
Overhead Line Conductors and Devices, Distribution
- 30 Line conductor
- 31 connector or clamp
- 32 Splice or deadend
- 33 Jumper
- 34 Insulator
- 35 Lightning arrestor, line
- 36 Fuse cutout damaged/malfunction/maintenance
- 37 OCR or sectionalizer damage/malfunction/maintenance
- 39 Overhead distribution line, other
Underground Conductor or Devices, Distribution
- 40 Primary cable
- 41 Splice or fitting
- 42 Switch
- 43 Lightning arrestor for URD
- 44 Secondary cable or fitting
- 49 Underground, other
Line Transformer
- 50 Transformer bad, replaced
- 51 Transformer fuse or breaker, refused or reset
- 52 transformer lightning arrestor
Secondaries and Services
- 60 Secondary or Service conductor
- 61 Meter or meter loop
- 62 Security light or street light
- 69 Other
Unknown
- 99 Open OCR, sectionalizer or fuse, source of difficulty not known
Cause of Interruption
Power Supplier
- 00 Power supplier
Scheduled
- 10 Construction
- 11 Maintenance
- 19 Other
Major Storm Disaster
- 20 Storm damage
Equipment or Installation
- 30 Material or equipment fault
- 31 Installation fault
- 32 Conductor sag or clearance not adequate
- 39 Faulty material or installation, other
Age or Deterioration
- 40 Decay
- 41 Woodpeckers
- 42 Corrosion or abbrasion
- 43 Contamination / Leakage
- 44 Moisture
- 45 Electrical overload
- 49 Age or deterioration, other
Weather
- Lightning
- 51 Wind not trees
- 52 Ice, sleet, frost, not trees
- 53 Trees and ice
- 54 Trees other
- 59 Weather, other
Birds or Animals
- 60 Small animals or birds Short circuit
- 61 Large animals Affecting pole or guy
- 69 Birds or animals ,other not woodpeckers
Member or Public
- 70 Vehicle or machinery
- 71 Aircraft
- 72 Public accidents, other
- 73 Vandalism
- 74 Fire
- 79 activities of the public, other
unknown
- 99 Cause of interruption not known