Actions

Difference between revisions of "PSR-300/400 Software and USB Support"

From The RadioReference Wiki

m (moved PSRE screenshot up by relevant section, made thumbnail)
 
(43 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
This article applies to the following scanners:
 
This article applies to the following scanners:
 
* GRE [[PSR-300]]  
 
* GRE [[PSR-300]]  
* GRE [[PSR-400]]
+
* GRE [[PSR-400]]
 +
* RS [[Pro-97]]
 +
* RS [[Pro-2055]]
 
* RS [[Pro-163]]
 
* RS [[Pro-163]]
 
* RS [[Pro-164]]
 
* RS [[Pro-164]]
  
Note that these scanners cannot be computer controlled, or perform logging operations while scanning. It's not provided for in the firmware
+
Note that these scanners cannot be computer controlled, or perform logging operations while scanning. It's not provided for in the firmware<br>
 +
 +
These procedures assume the scanner has the latest firmware. To determine the firmware version, follow this procedure: <br>
 +
* Turn the scanner off
 +
* Turn the scanner on
 +
* While the "Welcome" message is displayed, press the '3' key
 +
 
  
 
==Software==
 
==Software==
With the exception of Scancat (which has its own Yahoo group) the authors of the other programs can be reached on the [http://www.radioreference.com/forums/scanning-software-discussion-support/ software] forum. Software titles in '''bold''' can connect to the database to download data. This requires a purchase of a [http://www.radioreference.com/apps/subscription/ premium subscription].
+
The authors of the other programs can be reached on the [http://www.radioreference.com/forums/scanning-software-discussion-support/ software] forum. Software titles in '''bold''' can connect to the database to download data. This requires a purchase of a [http://www.radioreference.com/apps/subscription/ premium subscription].
 +
 
 +
 
 +
There are no Mac-native solutions for programming. See this [http://www.scannermaster.com/Mac_Users_of_Police_Scanner_Radios_s/575.htm article] from Scanner Master for alternatives.
 +
 
  
 
* '''[http://www.butel.nl/ ARC300]'''
 
* '''[http://www.butel.nl/ ARC300]'''
** Also supports the [[Pro-97]] and [[Pro-2055]]  
+
** [http://www.radioreference.com/radioshack/?a=order Radio Shack Scanner Programming Software Licensing]
 +
** [[Radio Shack Programming Software Free Trial]]
 +
** See the [[Radio Shack Scanner Programming Software Support]] article for instructions on installation and registering the software
 +
 
* '''[http://www.starrsoft.com/software/win97/default.asp Win97]'''
 
* '''[http://www.starrsoft.com/software/win97/default.asp Win97]'''
** Also supports the [[Pro-97]] and [[Pro-2055]]
+
**'''Note:''' The Starrsoft [http://www.starrsoft.com/ website] has been up and down numerous times in the last year. The status of the author/owner (Don Starr) is unknown
* '''[http://www.psredit.com/psredit300/index.html PSREdit 300]'''
+
 
** Also supports the [[Pro-97]] and [[Pro-2055]]
+
* '''[http://www.psredit.com/psredit300/index.html PSREdit300]'''
** [http://groups.yahoo.com/group/PSREdit300/ PSREdit300 Yahoo group]
+
** [[Software Setup For Linux]]
** [[PSREdit_with_Wine|Howto with Wine/Linux]]
+
 
 
* [http://www.psredit.com/psr300dl/index.html PSR300DL] Clone utility
 
* [http://www.psredit.com/psr300dl/index.html PSR300DL] Clone utility
 +
 
* [http://www.scancat.com/scancat-lite-plus.html Scancat Lite Plus]
 
* [http://www.scancat.com/scancat-lite-plus.html Scancat Lite Plus]
** [http://groups.yahoo.com/group/Scancat/ Scancat Yahoo group]
 
 
; USB Support
 
; USB Support
* [http://www.greamerica.com/scanner_accessories.html GRE USB Cable]
+
* Please see the [[Connecting scanners via USB]] article for USB cables to connect your PC to the scanner
* [http://rsk.imageg.net/graphics/uc/rsk/Support/SoftwareDownload/2000163.exe Radio Shack USB Cable Driver]
 
** Do '''NOT''' use the 3 inch adapter supplied with this unit.
 
  
 
== Setting Custom Tables for rebanded 800MHz systems ==
 
== Setting Custom Tables for rebanded 800MHz systems ==
[[Image:WIN97 Trunking Tables.jpg|thumb|300px|right|PSREdit300 Screenshot (click to enlarge)]]
+
* If you have a [http://www.radioreference.com/apps/subscription/ premium subscription], software that supports the web service will download the correct system type and custom tables automatically.
 +
* Before proceeding, look at the system type. If the system is a Motorola type;
 +
** Those systems that say ''APCO-25 Common Air Interface Exclusive'' cannot be tracked by the scanners covered in this article. A [[:Category:Digital Scanners|digital trunktracker]] is required to track these systems.
 +
** Any talkgroup marked with a 'D' in the '''Mode''' column of the database is digital, and therefore cannot be received by scanners in this article.
 +
** Look at all the frequencies. If the 4th decimal position is a '5' in every frequency, then you '''may''' be able to reprogram without firmware updates or a custom table. If '''any''' of the frequencies have a '0' then updating the scanner will be required to properly track this system
 +
* EDACS type systems will only need to be reprogrammed with the new rebanded frequencies. No firmware fixes are required to track these systems.
 +
* '''NOTE:''' Neither the PRO-97 nor PRO-2055 can be modified for rebanding. 
 +
 
 +
 
 +
===ARC300===
 +
[[Image:Arc300 reband.jpg|thumb|300px|right|ARC300 Screenshot (click to enlarge)]]
 +
* Make sure you run ARC300 V1.1 or higher
 +
* In the bank setup window set the Mot800 System Type to 'Custom/Rebanded'
 +
* Upload data to scanner and scanner will now track rebanded systems
 +
 
 +
 
 
===PSREdit300===
 
===PSREdit300===
 +
 
* Start PSREdit300.
 
* Start PSREdit300.
 
* Download your current configuration from your scanner.
 
* Download your current configuration from your scanner.
Line 43: Line 72:
  
 
===Win97===
 
===Win97===
* Make sure the scanner contains firmware 1.06 or later:
+
[[Image:WIN97 Trunking Tables.jpg|thumb|300px|right|WIN97 Screenshot (click to enlarge)]]
** Turn the scanner off
+
 
** Turn the scanner on
 
** While the "Welcome" message is displayed, press the '3' key
 
** If the Application version shown is not 1.06 or later, you must install an updated firmware version - visit the [http://www.greamerica.com/support GRE] or [http://www.radioshack.com RadioShack] web site as appropriate for your scanner and download/install the update.
 
 
* Start Win97
 
* Start Win97
 
* If you don't already have the scanner's programming saved, download it into Win97
 
* If you don't already have the scanner's programming saved, download it into Win97
Line 57: Line 83:
 
* Repeat, as necessary, for other banks (each bank has its own table settings)
 
* Repeat, as necessary, for other banks (each bank has its own table settings)
 
* Upload the data to the scanner
 
* Upload the data to the scanner
 +
 +
  
  
 
[[Category:Analog Trunktrackers]]
 
[[Category:Analog Trunktrackers]]
 
[[Category:Handheld Scanners]]
 
[[Category:Handheld Scanners]]
[[Category:Trunking Scanners]]
 
 
[[Category:Mobile Scanners]]
 
[[Category:Mobile Scanners]]
[[Category:Software Applications]]
+
[[Category:Programming FAQs and Tips for GRE Scanners]]
 +
[[Category:Programming FAQs and Tips for Radio Shack Scanners]]
 +
[[Category:Software for GRE Scanners]]
 +
[[Category:Software for Radio Shack Scanners]]

Latest revision as of 21:48, 28 December 2020

This article applies to the following scanners:

Note that these scanners cannot be computer controlled, or perform logging operations while scanning. It's not provided for in the firmware

These procedures assume the scanner has the latest firmware. To determine the firmware version, follow this procedure:

  • Turn the scanner off
  • Turn the scanner on
  • While the "Welcome" message is displayed, press the '3' key


Software

The authors of the other programs can be reached on the software forum. Software titles in bold can connect to the database to download data. This requires a purchase of a premium subscription.


There are no Mac-native solutions for programming. See this article from Scanner Master for alternatives.


  • Win97
    • Note: The Starrsoft website has been up and down numerous times in the last year. The status of the author/owner (Don Starr) is unknown
USB Support

Setting Custom Tables for rebanded 800MHz systems

  • If you have a premium subscription, software that supports the web service will download the correct system type and custom tables automatically.
  • Before proceeding, look at the system type. If the system is a Motorola type;
    • Those systems that say APCO-25 Common Air Interface Exclusive cannot be tracked by the scanners covered in this article. A digital trunktracker is required to track these systems.
    • Any talkgroup marked with a 'D' in the Mode column of the database is digital, and therefore cannot be received by scanners in this article.
    • Look at all the frequencies. If the 4th decimal position is a '5' in every frequency, then you may be able to reprogram without firmware updates or a custom table. If any of the frequencies have a '0' then updating the scanner will be required to properly track this system
  • EDACS type systems will only need to be reprogrammed with the new rebanded frequencies. No firmware fixes are required to track these systems.
  • NOTE: Neither the PRO-97 nor PRO-2055 can be modified for rebanding.


ARC300

ARC300 Screenshot (click to enlarge)
  • Make sure you run ARC300 V1.1 or higher
  • In the bank setup window set the Mot800 System Type to 'Custom/Rebanded'
  • Upload data to scanner and scanner will now track rebanded systems


PSREdit300

  • Start PSREdit300.
  • Download your current configuration from your scanner.
  • Switch to the Scanning Banks Tab
  • Use the bank selector to switch to the rebanded bank.
  • In the 800MHz system type area, change the pulldown box from standard to "Multi-Tables"
  • Click on the "Edit Tables" button.
  • Click on the "800 Rebanded" button.
  • Click on "Apply"
  • Repeat from the Switch to bank step for each bank with a rebanded system.
  • Upload the new configuration to your scanner.

Your scanner should now track the rebanded system correctly.

Win97

WIN97 Screenshot (click to enlarge)
  • Start Win97
  • If you don't already have the scanner's programming saved, download it into Win97
  • Click on the "Channels" tab and navigate to the bank that contains the system that is rebanded
  • Select the "Multi-table" item in the "MOT 800 MHz" group near the top-right of the page
  • Click on the "Extended Tables" button
  • Select "800 MHz Rebanded" under "'Standard' band plans"
  • Click the OK button
  • Repeat, as necessary, for other banks (each bank has its own table settings)
  • Upload the data to the scanner