Difference between revisions of "Saskatchewan P25 and Trunktrackers"
From The RadioReference Wiki
Line 18: | Line 18: | ||
* To trunktrack these systems the [[Pro-96]]/[[Pro-2096]] must have custom extended tables programmed with [[Win96]] software. These Radio Shack scanner models require a different set of custom trunking tables for every tower site in the system unless a site is used over again at another location in the Province. Channel #1 is 138.0150 and the last channel #100 is 139.5000. With this information the custom tables can be programmed for any tower site in the system. | * To trunktrack these systems the [[Pro-96]]/[[Pro-2096]] must have custom extended tables programmed with [[Win96]] software. These Radio Shack scanner models require a different set of custom trunking tables for every tower site in the system unless a site is used over again at another location in the Province. Channel #1 is 138.0150 and the last channel #100 is 139.5000. With this information the custom tables can be programmed for any tower site in the system. | ||
* Tx Frequency Range 138-139.5000 MHz | * Tx Frequency Range 138-139.5000 MHz | ||
− | * Rx Frequency Range | + | * Rx Frequency Range 136.4150-137.9000 MHz |
* Base = 138.000 in all cases | * Base = 138.000 in all cases | ||
− | * Step = | + | * Step = 5.0 in all cases |
− | + | * Channel spacing is 15 KHz | |
===Pro-96/2096 Custom Extended Tables=== | ===Pro-96/2096 Custom Extended Tables=== | ||
====Site #001 Regina Downtown==== | ====Site #001 Regina Downtown==== | ||
Line 34: | Line 34: | ||
|00 | |00 | ||
|00 | |00 | ||
− | | | + | |102 |
|00 | |00 | ||
|- | |- | ||
|01 | |01 | ||
− | | | + | |105 |
− | | | + | |135 |
− | | | + | |105 |
|- | |- | ||
|02 | |02 | ||
− | | | + | |138 |
− | | | + | |159 |
− | | | + | |138 |
|- | |- | ||
|03 | |03 | ||
− | | | + | |162 |
− | | | + | |192 |
− | | | + | |162 |
|- | |- | ||
|04 | |04 | ||
− | | | + | |210 |
− | | | + | |228 |
− | | | + | |210 |
|- | |- | ||
|05 | |05 | ||
− | | | + | |231 |
− | | | + | |249 |
− | | | + | |231 |
|- | |- | ||
|} | |} | ||
Line 76: | Line 76: | ||
|00 | |00 | ||
|00 | |00 | ||
− | | | + | |105 |
|00 | |00 | ||
|- | |- | ||
|01 | |01 | ||
− | | | + | |108 |
− | | | + | |174 |
− | | | + | |108 |
|- | |- | ||
|02 | |02 | ||
− | | | + | |177 |
− | | | + | |198 |
− | | | + | |177 |
|- | |- | ||
|} | |} | ||
Line 103: | Line 103: | ||
|00 | |00 | ||
|00 | |00 | ||
− | | | + | |102 |
|00 | |00 | ||
|- | |- | ||
|01 | |01 | ||
− | | | + | |96 |
− | | | + | |219 |
− | | | + | |96 |
|- | |- | ||
|02 | |02 | ||
− | | | + | |222 |
− | | | + | |261 |
− | | | + | |222 |
|- | |- | ||
|} | |} | ||
Line 130: | Line 130: | ||
|00 | |00 | ||
|00 | |00 | ||
− | | | + | |06 |
|00 | |00 | ||
|- | |- | ||
|01 | |01 | ||
− | | | + | |09 |
− | | | + | |42 |
− | | | + | |09 |
|- | |- | ||
|02 | |02 | ||
− | | | + | |45 |
− | | | + | |72 |
− | | | + | |45 |
|- | |- | ||
|03 | |03 | ||
− | | | + | |75 |
− | | | + | |168 |
− | | | + | |75 |
|- | |- | ||
|04 | |04 | ||
− | | | + | |171 |
− | | | + | |192 |
− | | | + | |171 |
|- | |- | ||
|} | |} |
Revision as of 20:23, 7 October 2010
Contents
Trunktracker Information
- These M/A-COM P25ip Systems control channels use Multi-Block Messaging Operation for Explicit Group/Voice Channel Grants.
- All tower sites share the same system ID of HEX#00A/DEC#10 and the same WACN of HEX#0000A/DEC#10 and the same NAC of 10.
- These scanners will decode and trunktrack these systems, but older models may not;
The Radio Shack Pro-96/Pro-2096 can not decode the multi-block messages sent by the control channel so they may only trunk a single channel on a system. The BC250D and BC785D can not decode the 9600-baud rate control channel so it will not trunktrack these systems. The scanner must be able to operate in P25 9600 baud Explicit Mode.
Pro-96/2096 Trunking Information
- To trunktrack these systems the Pro-96/Pro-2096 must have custom extended tables programmed with Win96 software. These Radio Shack scanner models require a different set of custom trunking tables for every tower site in the system unless a site is used over again at another location in the Province. Channel #1 is 138.0150 and the last channel #100 is 139.5000. With this information the custom tables can be programmed for any tower site in the system.
- Tx Frequency Range 138-139.5000 MHz
- Rx Frequency Range 136.4150-137.9000 MHz
- Base = 138.000 in all cases
- Step = 5.0 in all cases
- Channel spacing is 15 KHz
Pro-96/2096 Custom Extended Tables
Site #001 Regina Downtown
Site | Name | Freqs | |||||
---|---|---|---|---|---|---|---|
10-005 (A-5) | Regina - SaskPower Head Office | 138.510000c | 138.675000c | 138.795000c | 139.035000c | 139.140000c | 139.245000c |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 102 | 00 |
01 | 105 | 135 | 105 |
02 | 138 | 159 | 138 |
03 | 162 | 192 | 162 |
04 | 210 | 228 | 210 |
05 | 231 | 249 | 231 |
Site #002 Pilot Butte
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-002 (A-2) | Alsask | 138.450000a | 138.555000a | 138.780000c | 139.275000a |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 105 | 00 |
01 | 108 | 174 | 108 |
02 | 177 | 198 | 177 |
Site #071 Fort Qu'Appelle
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-071 (A-47) | Fort Qu'Appelle | 138.240000a | 138.465000a | 139.095000c | 139.305000a |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 102 | 00 |
01 | 96 | 219 | 96 |
02 | 222 | 261 | 222 |
Site #081 Moose Jaw
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-181 (A-B5) | Pasqua | 138.030000c | 138.210000c | 138.360000c | 138.720000c |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 06 | 00 |
01 | 09 | 42 | 09 |
02 | 45 | 72 | 45 |
03 | 75 | 168 | 75 |
04 | 171 | 192 | 171 |
Possible Firmware Issues
- It appears that version 1.4 firmware is unable to trunktrack this system. Version 1.3 firmware seems to be required until/if RS issues any further fixes (thanks VE5WIL)
Refresh this page from the latest database entry