Line 64: Line 64:
 
* Key Lock
 
* Key Lock
 
* On-Air Cloning
 
* On-Air Cloning
 +
* PC Programming and Control
 +
* [[Priority Scan]] with Priority Plus
 
* [[P25 audio decode level adjustment]]
 
* [[P25 audio decode level adjustment]]
 
* Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel
 
* Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel
 
* Quick Search
 
* Quick Search
* PC Programming and Control
 
* [[Priority Scan]] with Priority Plus
 
 
* [[Repeater Reverse]]
 
* [[Repeater Reverse]]
 
* [[SAME]] Weather Alert
 
* [[SAME]] Weather Alert

Revision as of 09:26, 30 April 2021

LCD Close up
Bearcat BCD396T digital Trunktracker IV
3966.jpg
3 batteries
Belt Clip View


Uniden's APCO-25 Capable portable Trunktracker IV Scanner with Dynamic Memory Architecture.


Specifications

Limits

  • Channels: 6000 maximum
  • Systems: 400 maximum
  • Groups per system: 20 maximum
  • Talkgroups per trunked system: 200 maximum
  • Scan Rate: 100 channels per second (conventional mode)
  • System Quick Key range: 0-99
  • Group Quick Key range: 0-9
  • Custom Search Ranges: 10
  • Preprogrammed Service Search Bands: 12

Frequency Coverage

  • (North American Model BCD396T)
  • 25.0000 - 512.0000 MHz
  • 764.0000 - 775.9875 MHz
  • 794.0000 - 823.9875 MHz
  • 849.0125 - 868.9875 MHz
  • 894.0125 - 956.0000 MHz
  • 1240.0000 - 1300.0000 MHz
  • (Australia/New Zealand Model UBCD396T)
  • 25.0000 - 512.0000 MHz
  • 764.0000 - 775.9875 MHz
  • 794.0000 - 956.0000 MHz
  • 1240.0000 - 1300.0000 MHz

Power Requirements

Features

  • Adaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systems
  • Adjustable Hold (scan duration 0-255 sec) per system, custom or service search
  • Adjustable (0-5 sec) scan delay
  • Analog and Digital AGC
  • Antenna Connector: SMA (w/BNC adapter)
  • APCO25 Digital Audio decoding
  • Battery level display
  • Battery saver
  • Blue LCD and Keypad Backlight
  • Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc) with 10 custom bands
  • Channel Alert
  • Uniden Close Call, with Close Call Do Not Disturb (with version 3 firmware), Close Call Priority (or Primary), and Close Call Temporary Store
  • Custom Search — lets you program up to 10 search ranges
  • Compatible with BC-RH96 Remote Head
  • Data Skip
  • DCS/CTCSS Rapid Decode
  • Duplicate Channel Alert
  • Fire Tone Out alert
  • Frequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked system
  • Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
  • Key Lock
  • On-Air Cloning
  • PC Programming and Control
  • Priority Scan with Priority Plus
  • P25 audio decode level adjustment
  • Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel
  • Quick Search
  • Repeater Reverse
  • SAME Weather Alert
  • Search with Scan for Service and Custom Searches
  • Signal Strength display
  • Strong signal attenuation
  • Upgradeable firmware
  • Weather Alert Priority
  • Wired Cloning (Will only Clone to another BCD396T)
  • Supported step sizes: 5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHz.
  • 100 Quick Keys
  • 16 character text tagging for each system, group, channel, talkgroup, search range, Tone-out, and SAME group
  • 12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, TV Broadcast, and Special (Itinerant)

RR System Compatibility

This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range:

  • System Types:
    • Motorola Type I
    • Motorola Type II
    • Motorola Type IIi Hybrid
    • Motorola Type II Smartnet
    • Motorola Type II Smartzone
    • Motorola Type II Smartzone Omnilink
    • Motorola Type II VOC
    • EDACS Standard (Wide)
    • EDACS Standard Networked
    • EDACS Narrowband (Narrow)
    • EDACS Narrowband Networked
    • EDACS SCAT
    • EDACS ESK (version 3.0 firmware or later required)
    • LTR Standard
    • Project 25 Standard
  • System Voices:
    • Analog
    • Analog and APCO-25 Common Air Interface
    • APCO-25 Common Air Interface Exclusive

Mods

Tips & Tricks

  • Frequency 'tune' mode: While in scanning mode, press HOLD, key in the frequency, then press HOLD. The scanner stays on this frequency. This also works for talkgroups (hit . twice for a dash). An error message is displayed if you enter a talkgroup while scanning a conventional system.