[[image:Bcd996t 100505.gif|right|400px|BCD996T - Click image to view in full]]
 
[[image:Bcd996t 100505.gif|right|400px|BCD996T - Click image to view in full]]
== Overview ==
+
 
 
Uniden's Base/Mobile Digital Trunktracker scanner with [[Dynamic Memory Architecture]] and GPS Support.
 
Uniden's Base/Mobile Digital Trunktracker scanner with [[Dynamic Memory Architecture]] and GPS Support.
  
 
Started Shipping June 2006.
 
Started Shipping June 2006.
 +
 +
[http://www.uniden.com/press/docs/BCD996T_Release_FNL.pdf Uniden BCD-996T Press Release]
  
 
==Specifications==
 
==Specifications==
===Limits===
+
'''Limits'''
 
* Channels: 6000 maximum
 
* Channels: 6000 maximum
 
* Systems: 500 maximum
 
* Systems: 500 maximum
Line 12: Line 14:
 
* Groups per system: 20 maximum
 
* Groups per system: 20 maximum
 
* Talkgroups per trunked system: 250 maximum
 
* Talkgroups per trunked system: 250 maximum
 +
 
* Scan Rate: 100 channels per second (conventional mode)
 
* Scan Rate: 100 channels per second (conventional mode)
 
* System Quick Key range: 0-99
 
* System Quick Key range: 0-99
Line 18: Line 21:
 
* Preprogrammed Service Search Bands: 13
 
* Preprogrammed Service Search Bands: 13
  
===Frequency Coverage===
+
'''Frequency Coverage'''
 
* 25 - 512 MHz
 
* 25 - 512 MHz
 
* 764 - 776 MHz
 
* 764 - 776 MHz
Line 24: Line 27:
 
* 1240 - 1300 MHz
 
* 1240 - 1300 MHz
  
===Power requirements===
+
'''Features'''
* 11.0V to 16.6V DC
+
* [[Rebanding]] Supported? <font color=green> YES </font>
 
 
=== Antenna Connector ===
 
* BNC
 
 
 
=== Features ===
 
 
* [[Project_25|APCO25 Digital Audio]] decoding
 
* [[Project_25|APCO25 Digital Audio]] decoding
* [[Close Call]], with CCDND and CCPriority
+
* APCO Auto Adjust Threshold
 +
* [[TrunkTracker IV]] with Control-Channel Only scanning and [[I-Call]] monitoring
 +
* [[Uniden Multi-Site Trunking]] allows independent system sites to share common talk group channel lists.
 +
* [[Uniden_Scanner_GPS_Features|Location-based scanning and GPS information display]]
 +
* Startup Configuration – lets you set systems to be automatically locked or unlocked during power-up.
 +
* [[Close Call]], with [[Uniden Close Call#Close Call Do Not Disturb|Close Call Do Not Disturb]], [[Uniden Close Call#Close Call Priority|Close Call Priority]], and [[Uniden Close Call#Close Call Temporary Store|Close Call Temporary Store]].
 
* [[Fire Tone Out]] Alert
 
* [[Fire Tone Out]] Alert
 +
* Search with Scan
 
* [[AGC]]
 
* [[AGC]]
 
* [[SAME]] Weather Alert
 
* [[SAME]] Weather Alert
 
* [[DCS]]/[[CTCSS]] [[Automatic_CTCSS_identification|Rapid Decode]]
 
* [[DCS]]/[[CTCSS]] [[Automatic_CTCSS_identification|Rapid Decode]]
 
* Compatible with [[BC-RH96]] Remote Head
 
* Compatible with [[BC-RH96]] Remote Head
* [[TrunkTracker IV]] with Control-Channel Only scanning and [[I-Call]] monitoring
+
* Two-Color Backlighting-Lets you choose either red or green backlighting for the display/keypad.
 +
* Three-Level Backlighting-Lets you set the display/keypad backlight to any of three levels (or off).
 
* LCD and Keypad Backlight
 
* LCD and Keypad Backlight
 
* [[Priority Scan]] with Priority Plus
 
* [[Priority Scan]] with Priority Plus
 
* Signal Strength display
 
* Signal Strength display
 
* Trunking Activity Indicators
 
* Trunking Activity Indicators
* 16 character text tagging for each system, site, group, channel, talkgroup, search range, and [[SAME]] group
+
* 16 character text tagging for each system, site, group, channel, talkgroup, search range, GPS location, tone-out, and [[SAME]] group
 
* Configurable scan delay
 
* Configurable scan delay
 
* Strong signal attenuation
 
* Strong signal attenuation
* Downloadable firmware
+
* Upgradeable firmware
* Temporary lockout
+
* [http://wiki.radioreference.com/index.php/BCT15#Advanced_.28and_much_requested.29_Features Temporary lockout]
 
* [[Channel Alert]]
 
* [[Channel Alert]]
 
* [[Repeater Reverse]]
 
* [[Repeater Reverse]]
 
* Frequency autostore and Talkgroup ID autostore
 
* Frequency autostore and Talkgroup ID autostore
 
* Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc)
 
* Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc)
* [[Uniden_Scanner_GPS_Features|Location-based scanning and GPS information display]]
 
 
== User Manual and Related Documentation ==
 
 
[http://www.uniden.com/pdf/BCD996Tom.pdf BCD996T User Manual]
 
 
[http://www.uniden.com/index/downloadfile.cfm?product=BCD996T&dwnld_id=126 Control Codes for BCD996]
 
 
Talkgroup and Frequency display when scanning:
 
 
Use display mode #2: Toggling the Display Mode
 
To change the display so the channel and frequency or Talk Group ID appear
 
instead of extended channel information, hold on any channel then press F + [0].
 
The scanner displays Display Mode 2. To return to Mode 1, press F + [0]
 
Mode1 indicates the channel data under the Channel Name.
 
Mode2 indicates the frequencies under the Channel Name for Conventional
 
systems or the TGID number for Trunked systems.
 
 
==Digital/Analog AGC Tweak Procedures ==
 
 
[[Uniden_Digital_AGC_Tweak_Procedures]]
 
 
 
==Related Pages==
 
 
[[BCD996T QandA]]
 
 
[[BC-RH96]] Remote Head
 
 
[[media:Bc996discriminatortap.jpg|JPEG of discriminator tap point]]
 
 
[[Uniden scanner test modes]]
 
 
== Feature Summary ==
 
* [[Rebanding]] Supported? <font color=green> YES </font>
 
 
* Startup Configuration – lets you set systems to be automatically locked or unlocked during power-up.
 
 
* Single-Handed Function Operation
 
* Single-Handed Function Operation
 +
* Alert + -- sets the scanner to be silent except for "alert" channels or events.
 
* Dropout Delay
 
* Dropout Delay
 
* Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel.
 
* Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel.
 
* Quick Search
 
* Quick Search
* "Soft" Search Keys – let you assign search ranges to front-panel keys.
+
* “SOFT Search Keys – let you assign search ranges to front-panel keys.
 
* 500 (250 Temporary + 250 Permanent) Search Lockouts
 
* 500 (250 Temporary + 250 Permanent) Search Lockouts
 
* Duplicate Input Alert
 
* Duplicate Input Alert
 
* Data Skip
 
* Data Skip
* APCO Auto Adjust Threshold
 
* Multi-Site Trunking – allows independent system sites to share common talk group channel lists.
 
 
* Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
 
* Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
 
* Key Lock
 
* Key Lock
* PC Control
+
* PC Programming and Control
 
* Wired Cloning
 
* Wired Cloning
 
* On-Air Programming
 
* On-Air Programming
 
* Memory Back Up
 
* Memory Back Up
* [http://www.grove-ent.com/SCANNERPROGRAMMING.htm Scanner Programming: Man-Machine Interface]
 
** 'Getting the Most from the new Uniden Scanners' by Paul Opitz
 
  
Physical Dimensions:
+
'''Physical Dimensions:'''
Width 7.33    Height 2.21    Depth 5.94
+
* Width 7.33    Height 2.21    Depth 5.94
  
== Advanced Features ==
+
'''Power requirements'''
 +
* 11.0V to 16.6V DC
  
=== Multi-Site Trunking ===
+
'''Antenna Connector'''
See [[Uniden Multi-Site Trunking]].
+
* BNC
 
 
=== Temporary Lockout ===
 
  
 +
== Advanced Features ==
 +
'''Temporary Lockout-'''
 
Pressing L/O one time while on a channel temporarily locks out that channel.  
 
Pressing L/O one time while on a channel temporarily locks out that channel.  
 
Pressing F+L/O one time while on a system temporarily locks out that system.
 
Pressing F+L/O one time while on a system temporarily locks out that system.
Line 125: Line 91:
 
Temporary lockouts are removed when power is cycled.
 
Temporary lockouts are removed when power is cycled.
  
=== Startup Configuration ===
+
'''Startup Configuration-'''
 
 
 
Pressing a number button while powering on the scanner automatically unlocks all systems assigned to that startup key and automatically locks all systems assigned to a different startup key (unassigned systems are not affected).
 
Pressing a number button while powering on the scanner automatically unlocks all systems assigned to that startup key and automatically locks all systems assigned to a different startup key (unassigned systems are not affected).
  
=== [[Uniden Close Call|Close Call]] Do-Not-Disturb ===
+
'''“Soft Search Keys-'''
 
 
See [[Uniden Close Call#Close Call Do Not Disturb|Close Call Do Not Disturb]]
 
 
 
=== Soft Search Keys ===
 
 
 
 
Let you program the keypad’s secondary functions to turn on/off specified search ranges.
 
Let you program the keypad’s secondary functions to turn on/off specified search ranges.
  
=== Two-Color Backlighting ===
+
'''Single-Handed Function Operation-'''
 +
Tap Function to access F+ key presses. 5 seconds after your last key press, the scanner reverts to non F+ entry (or press Function again to revert sooner).
  
Lets you choose either red or green backlighting for the display/keypad.
+
'''Alert Plus-'''
 +
Sets the scanner for "wife and girlfriend" mode. Silences all channels and audio except for those channels and events that have an assigned alert.
  
=== Single-Handed Function Operation ===
+
==Reviews==
 +
* [[Scan Cape Cod's Mini-Review]]
  
Tap Function to access F+ key presses. 5 seconds after your last key press, the scanner reverts to non F+ entry (or press Function again to revert sooner).
+
==Related Pages==
 
+
* [[BCD996T QandA]]
=== Close Call Temporary Store ===
+
* [[DMA Problems|Uniden Dynamic Memory Scanner Problems]]
 
+
* [http://www.grove-ent.com/SCANNERPROGRAMMING.htm Scanner Programming: Man-Machine Interface]
When this option is turned on, when the scanner gets a Close Call "hit", it temporarily saves the hit and includes that frequency when scanning. The scanner keeps the last 10 hits (older hits are erased by newer ones). Hits are lost when power is cycled. You can store a hit into memory by pressing "E" when on that frequency.
+
** 'Getting the Most from the new Uniden Scanners' by Paul Opitz
 +
* [[Uniden_Digital_AGC_Tweak_Procedures]]
 +
* [http://www.uniden.com/pdf/BCD996Tom.pdf BCD996T User Manual]
 +
* [[media:Bc996discriminatortap.jpg|JPEG of discriminator tap point]]
 +
* [[Uniden scanner test modes]]
 +
* [http://www.uniden.com/index/downloadfile.cfm?product=BCD996T&dwnld_id=126 Control Codes for BCD996]
  
 
==PC Programming and Control==
 
==PC Programming and Control==
 
 
* [http://www.butelsoftware.com BuTel Software products]
 
* [http://www.butelsoftware.com BuTel Software products]
 
** Clone996 backup & restore utility
 
** Clone996 backup & restore utility
Line 164: Line 131:
 
* [http://www.scanstar.com/products/tselite.htm Trunkstar Elite]
 
* [http://www.scanstar.com/products/tselite.htm Trunkstar Elite]
 
* [http://www.scanstar.com/products/tsepro.htm Trunkstar Elite Pro]
 
* [http://www.scanstar.com/products/tsepro.htm Trunkstar Elite Pro]
 
==Reviews==
 
* [[Scan Cape Cod's Mini-Review]]
 
 
== Press Release ==
 
 
[http://www.uniden.com/press/docs/BCD996T_Release_FNL.pdf Uniden BCD-996T Press Release]
 
  
 
==Yahoo Groups and Message Boards==
 
==Yahoo Groups and Message Boards==
Line 177: Line 137:
 
* [http://www.strongsignals.net/access/forums/viewforum.php?f=50&sid=a008fecb4f59406385d1ff0cbe328c9c Strong Signals BCD996T forum]
 
* [http://www.strongsignals.net/access/forums/viewforum.php?f=50&sid=a008fecb4f59406385d1ff0cbe328c9c Strong Signals BCD996T forum]
  
==Problems/Issues==
+
==Talkgroup and Frequency display when scanning==
See [[DMA Problems|Uniden Dynamic Memory Scanner Problems]]
+
 
 +
Use display mode #2: Toggling the Display Mode
 +
To change the display so the channel and frequency or Talk Group ID appear
 +
instead of extended channel information, hold on any channel then press F + [0].
 +
The scanner displays Display Mode 2. To return to Mode 1, press F + [0]
 +
Mode1 indicates the channel data under the Channel Name.
 +
Mode2 indicates the frequencies under the Channel Name for Conventional
 +
systems or the TGID number for Trunked systems.
  
 
==eBay Listings==
 
==eBay Listings==

Revision as of 15:01, 25 March 2007

BCD996T - Click image to view in full

Uniden's Base/Mobile Digital Trunktracker scanner with Dynamic Memory Architecture and GPS Support.

Started Shipping June 2006.

Uniden BCD-996T Press Release

Specifications

Limits

  • Channels: 6000 maximum
  • Systems: 500 maximum
  • Sites: 1000 maximum, 256 maximum per system
  • Groups per system: 20 maximum
  • Talkgroups per trunked system: 250 maximum
  • Scan Rate: 100 channels per second (conventional mode)
  • System Quick Key range: 0-99
  • Group Quick Key range: 0-9
  • Custom Search Ranges: 10
  • Preprogrammed Service Search Bands: 13

Frequency Coverage

  • 25 - 512 MHz
  • 764 - 776 MHz
  • 794 - 956 MHz
  • 1240 - 1300 MHz

Features

  • Rebanding Supported? YES
  • APCO25 Digital Audio decoding
  • APCO Auto Adjust Threshold
  • TrunkTracker IV with Control-Channel Only scanning and I-Call monitoring
  • Uniden Multi-Site Trunking allows independent system sites to share common talk group channel lists.
  • Location-based scanning and GPS information display
  • Startup Configuration – lets you set systems to be automatically locked or unlocked during power-up.
  • Close Call, with Close Call Do Not Disturb, Close Call Priority, and Close Call Temporary Store.
  • Fire Tone Out Alert
  • Search with Scan
  • AGC
  • SAME Weather Alert
  • DCS/CTCSS Rapid Decode
  • Compatible with BC-RH96 Remote Head
  • Two-Color Backlighting-Lets you choose either red or green backlighting for the display/keypad.
  • Three-Level Backlighting-Lets you set the display/keypad backlight to any of three levels (or off).
  • LCD and Keypad Backlight
  • Priority Scan with Priority Plus
  • Signal Strength display
  • Trunking Activity Indicators
  • 16 character text tagging for each system, site, group, channel, talkgroup, search range, GPS location, tone-out, and SAME group
  • Configurable scan delay
  • Strong signal attenuation
  • Upgradeable firmware
  • Temporary lockout
  • Channel Alert
  • Repeater Reverse
  • Frequency autostore and Talkgroup ID autostore
  • Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc)
  • Single-Handed Function Operation
  • Alert + -- sets the scanner to be silent except for "alert" channels or events.
  • Dropout Delay
  • Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel.
  • Quick Search
  • “SOFT Search Keys – let you assign search ranges to front-panel keys.
  • 500 (250 Temporary + 250 Permanent) Search Lockouts
  • Duplicate Input Alert
  • Data Skip
  • Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
  • Key Lock
  • PC Programming and Control
  • Wired Cloning
  • On-Air Programming
  • Memory Back Up

Physical Dimensions:

  • Width 7.33 Height 2.21 Depth 5.94

Power requirements

  • 11.0V to 16.6V DC

Antenna Connector

  • BNC

Advanced Features

Temporary Lockout- Pressing L/O one time while on a channel temporarily locks out that channel. Pressing F+L/O one time while on a system temporarily locks out that system.

Pressing L/O or F+L/O two times results in a permanent lockout. Pressing L/O for more than 3 seconds unlocks all channels in the current system (or all search lockouts if in a search). F+L/O for more than 3 seconds unlocks all systems.

Temporary lockouts are removed when power is cycled.

Startup Configuration- Pressing a number button while powering on the scanner automatically unlocks all systems assigned to that startup key and automatically locks all systems assigned to a different startup key (unassigned systems are not affected).

“Soft Search Keys- Let you program the keypad’s secondary functions to turn on/off specified search ranges.

Single-Handed Function Operation- Tap Function to access F+ key presses. 5 seconds after your last key press, the scanner reverts to non F+ entry (or press Function again to revert sooner).

Alert Plus- Sets the scanner for "wife and girlfriend" mode. Silences all channels and audio except for those channels and events that have an assigned alert.

Reviews

Related Pages

PC Programming and Control

Yahoo Groups and Message Boards

Talkgroup and Frequency display when scanning

Use display mode #2: Toggling the Display Mode To change the display so the channel and frequency or Talk Group ID appear instead of extended channel information, hold on any channel then press F + [0]. The scanner displays Display Mode 2. To return to Mode 1, press F + [0] Mode1 indicates the channel data under the Channel Name. Mode2 indicates the frequencies under the Channel Name for Conventional systems or the TGID number for Trunked systems.

eBay Listings