Actions

Difference between revisions of "BCD996XT"

From The RadioReference Wiki

Line 57: Line 57:
 
* '''EDACS [[ESK]] support'''
 
* '''EDACS [[ESK]] support'''
 
* '''Multi-color display backlight'''
 
* '''Multi-color display backlight'''
* '''* [[Uniden BCDx36HP Quick Keys and Number Tags|Number Tags]]'''
+
* ''' [[Uniden BCDx36HP Quick Keys and Number Tags|Number Tags]]'''
 
* '''[[Control Channel Data Output]]'''
 
* '''[[Control Channel Data Output]]'''
 
* [[Uniden Close Call]], with [[Uniden Close Call#Close Call Do Not Disturb|Close Call Do Not Disturb]], [[Uniden Close Call#Close Call Priority|Close Call Priority (or Primary)]], and [[Uniden Close Call#Close Call Temporary Store|Close Call Temporary Store]].
 
* [[Uniden Close Call]], with [[Uniden Close Call#Close Call Do Not Disturb|Close Call Do Not Disturb]], [[Uniden Close Call#Close Call Priority|Close Call Priority (or Primary)]], and [[Uniden Close Call#Close Call Temporary Store|Close Call Temporary Store]].

Revision as of 19:46, 2 May 2021

Bearcat BCD996XT digital Trunktracker IV

The BCD996XT Uniden's APCO-25 Capable desktop Trunktracker scanner with Dynamic Memory Architecture. This scanner became available to the market in July, 2009. It is an upgrade to the BCD996T. (The BCD996P2 is an upgrade to the BCD996XT.) Discontinued.

Specifications

Limits

  • Channels: 25,000 maximum
  • Systems: 500 maximum
  • Groups per system: 20 maximum
  • Talkgroups per trunked system: 500 maximum
  • Channels per conventional system: 1000 maximum
  • Scan Rate: 100 channels per second (conventional mode)
  • Search Rate: 300 steps per second (on 5 kHz steps)
  • System Quick Key range: 0-99
  • Group Quick Key range: 0-9
  • Custom Search Ranges: 10
  • Startup Keys: 10
  • System Number Tagging: 999
  • Channel Number Tagging: 999
  • Preprogrammed Service Search Bands: 12
  • Band Scope Span Range: 0.2 Mhz To 500 Mhz
  • Band Scope Step: 5 Khz To 100 Khz

Frequency Coverage

  • 25.0000 - 512.0000 MHz
  • 758.0000 - 823.9875 MHz
  • 849.0125 - 868.9875 MHz
  • 894.0125 - 960.0000 MHz
  • 1240.0000 - 1300.0000 MHz

FM Bandwidths

  • NFM: ~7.5 kHz deviation
  • FM: ~15 kHz deviation
  • FMB: ~75 kHz deviation
  • WFM: >100 kHz deviation

Power Requirements

  • Power requirements: AC Adapter (13.8V DC 750mA Regulated) (AD-1009 or equivalent).
  • DC:11V to 16.6V(Ext.DC Power Jack or DC Power Jack)
  • Power plug: 5.5mm outer diameter, 2.1mm inner diameter; Radio Shack size code "M"

Features

Bold features are newly added in this model over the BCD996T.

  • Can be updated to support Rebanding? YES
  • APCO25 Digital Audio decoding
  • NAC decoding
  • Support for P25 Conventional channels that include NAC and TGID user differentiation (P25 One-Frequency Trunk)
  • Adaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systems
  • TrunkTracker IV with Motorola Control Channel Only trunking and I-Call monitoring
  • Multi-Site support
  • NEW Display the Unit IDs (UID) found on trunk systems. Firmware 1.04.00 or newer is required. See the firmware link below for more information
  • EDACS ESK support
  • Multi-color display backlight
  • Number Tags
  • Control Channel Data Output
  • Uniden Close Call, with Close Call Do Not Disturb, Close Call Priority (or Primary), and Close Call Temporary Store.
  • GPS Support for Location Based Scanning, location alerts, and crows-flight navigation
  • Independent GPS Control of Sites and Channel Groups (vs. Systems and Sites)
  • 100 Quick Keys
  • Supported step sizes: 5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHz
  • Adjustable Band defaults
  • Individual channel volume offset
  • Intermediate Frequency Exchange - changes the IF used for a selected frequency to help avoid image and other mixer-product interference on a frequency.
  • Key Safe Mode - lets you hand the scanner to a novice user and prevent programming from being modified.
  • Private Systems - lets you flag a system so that it cannot be read out of the scanner or modified.
  • Band Scope - gives a graphic representation of signal activity.
  • Negative Channel dropout delay (forced resume) adjustable to 0-2,5,10,30, -2, -5, -10 seconds
  • DCS/CTCSS Rapid Decode
  • Temporary System, Site, Group, Channel, and Location Lockout
  • 500 (250 Temporary + 250 Permanent) Search Lockouts
  • Startup Configuration
  • Frequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked system
  • 16 character text tagging for each system, site, group, channel, talkgroup, search range, location, Tone-out, and SAME group
  • Compatible with BC-RH96 Remote Head
  • Analog and Digital AGC
  • Ability to flag a channel as Digital, Analog, or All
  • Quick Search
  • Search with Scan for Service and Custom Searches with assigned Quick Keys
  • 12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, Military Air, and Special (Itinerant)
  • Custom Search — lets you program up to 10 search ranges
  • 3 (vs. 6) Quick-Access Search Keys
  • Fire Tone Out alert
  • Fire Tone Out Search - built-in frequency counter displays the received tones.
  • Channel Alert
  • Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
  • Weather Alert Priority
  • SAME Weather Alert
  • Duplicate Channel Alert
  • Priority Scan with Priority Plus
  • Adjustable Priority check interval
  • Priority ID Scan on trunked systems
  • Preemptive Priority on Motorola analog systems
  • Signal Strength display
  • LCD and Keypad Backlight
  • Reversible Display - Lets you reverse the display to mount unit upside down (and hear the speaker from the top)
  • Adjustable Hold (scan duration 0-255 sec) per system, custom or service search
  • Strong signal attenuation
  • Upgradeable firmware
  • Repeater Reverse
  • Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc) with 10 custom bands
  • PC Programming and Control
  • Record Out - you can connect an output jack to a VOX controlled recorder or PC sound input to record the received audio.
  • Wired Cloning (Will only Clone to another BCD996XT)
  • DIN-E and ISO Vehicle Mountable sleeve included
  • Antenna Connector: BNC

RR System Compatibility

This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range:

  • System Voices:
    • Analog
    • Analog and APCO-25 Common Air Interface
    • APCO-25 Common Air Interface Exclusive

Preloaded Systems and their System Quick Keys

Press and hold 2,9, and Hold, power on the scanner to re-initialize the Memory and restore the Preloaded systems. When it asks do you wish to restore the preloaded systems press the E/Yes key. WARNING This will erase any personal programming you may have done to your DMA.

The preloaded system list for the BCD996XT:

SQK System

  • 21 Alaska ALMR
  • 22 Arkansas AWIN
  • 23 Colorado DTRS
  • 24 Connecticut State
  • 25 Delaware
  • 26 Georgia GEWIN
  • 27 Idaho IIMARS
  • 28 Illinois StarCom21
  • 29 Indiana SAFE-T
  • 30 Kansas KSICS
  • 31 Louisiana LATIE
  • 32 Mass State Sys [Analog]
  • 33 Michigan MPSCS
  • 34 Mississippi MWIN
  • 35 Montana StateSys
  • 36 NC VIPER
  • 37 Nevada SRS
  • 38 Ohio MARCS
  • 39 Rhode Isl RISCON
  • 40 SC Palmetto 800
  • 41 SDakotaState
  • 42 TX DPS
  • 43 Utah UCAN
  • 44 Virginia STARS
  • 45 WVirginia WVIRP
  • 46 WyoLink

Related Pages

External Links
Wiki Articles

Supporting Software

Message Boards/forums

RadioReference
Facebook
Groups.io
Twitter

BCD996XT Scanners for Sale


Return to Uniden Scanners