Actions

Difference between revisions of "Data Slicers"

From The RadioReference Wiki

Line 15: Line 15:
  
 
'''NOTE:''' Some TL081 IC's specifically the ST branded ones have the output on pin 6 instead of pin 1.
 
'''NOTE:''' Some TL081 IC's specifically the ST branded ones have the output on pin 6 instead of pin 1.
 +
 
'''NOTE:''' Additional filtering is required when using utilities for LTR Decoding.  The schematic may be viewed [[media:LTRDicer1.png|here]]
 
'''NOTE:''' Additional filtering is required when using utilities for LTR Decoding.  The schematic may be viewed [[media:LTRDicer1.png|here]]
  

Revision as of 14:04, 23 December 2006

Many applications featured on these pages require either the 2-Level FSK interface or the 4-Level FSK interface, otherwise known as a data slicer. You must build this interface, or buy it from some of sources listed at the bottom of the page. NOTE that these interfaces DO NOT provide computer control for your scanner, but rather they interface the output from your scanner so that the computer and application can decode the digital signals.

These interfaces connect to the discriminator output on you scanner (and ONLY the discriminator output) This is usually a connection inside of your scanner that must be made with a soldering iron.

The 2-Level Interface

The 2-Level Interface (also called the Hamcom interface) is required for most of the applications that are available for decoding digital signals today. There are numerous different version of this interface, but they all accomplish the same task. You can use the Hamcom Tuning Interface Application to test and adjust the performance.

2-Level General Hamcom Interface

Here is another schematic of the 2-Level interface based around the MAX232 chipset. This interface is very reliable and is reported to work VERY well with Trunker and Etrunker.

2-Level General Hamcom Interface

NOTE: Some TL081 IC's specifically the ST branded ones have the output on pin 6 instead of pin 1.

NOTE: Additional filtering is required when using utilities for LTR Decoding. The schematic may be viewed here

The 4-Level Interface

The 4-Level Interface is a new generation of interfaces that are required for the faster digital modes. For decoding Flex paging and RD-LAP MDT modes, this interface will be required. The only production application today that uses the 4-Level interface today is Pocflex. This interface will however have further uses when APCO-25 decoding becomes possible.

Description

Here is a schematic of the 2-level and 4-level interface combined into one interface.

Description

Another version of the 4-level interface with power supply can be found below:

Description

Purchasing an Interface