Actions

Difference between revisions of "Freescan General Options"

From The RadioReference Wiki

m
Line 15: Line 15:
 
* '''Key Safe''' - see the Key-Safe Mode section of the [http://marksscanners.com XT Easier to Read manuals] for a discussion of this parameter
 
* '''Key Safe''' - see the Key-Safe Mode section of the [http://marksscanners.com XT Easier to Read manuals] for a discussion of this parameter
 
* '''Use P25 Low-Pass Filter''' - See the [[P25 audio decode level adjustment]] article in the XT section for a discussion of this parameter
 
* '''Use P25 Low-Pass Filter''' - See the [[P25 audio decode level adjustment]] article in the XT section for a discussion of this parameter
 
 
 
* '''Use Global Attenuation'''  
 
* '''Use Global Attenuation'''  
 
* '''Enable Unit ID''' - Enables Unit ID logging. This option is for the XT scanners with the following firmware versions (or better);
 
* '''Enable Unit ID''' - Enables Unit ID logging. This option is for the XT scanners with the following firmware versions (or better);

Revision as of 20:34, 17 February 2011

FS General options.JPG

Welcome to the Freescan general options article.

General

  • See the priority section of the Easier to Read manuals for a discussion of these parameters:
    • Priority OFF
    • Priority ON
    • Priority ON +
  • Battery Save Set the scanner so it reduces the amount of power it needs if there are no transmissions (not on the XT handhelds?)

XT Specific

  • Key Lock - Deactivates the scanner's keys to help prevent accidentally changing the scanner's programming
  • Key Safe - see the Key-Safe Mode section of the XT Easier to Read manuals for a discussion of this parameter
  • Use P25 Low-Pass Filter - See the P25 audio decode level adjustment article in the XT section for a discussion of this parameter
  • Use Global Attenuation
  • Enable Unit ID - Enables Unit ID logging. This option is for the XT scanners with the following firmware versions (or better);
    • BCD996XT - 1.04.00
    • BCD396XT - 1.08.14
    • BC346XT - 1.05.00
    • BCT15X - 1.03.00


C-Ch Logging

  • This option creates a data stream that can be utilized by utilities such as UniTrunker
  • NOTE: This option must be turned off, or FreeScan will not connect to the scanner
  • Off - No data is sent
  • On - Control channel data is output
  • Extended - Control channel data and a description is output


  • Battery Charge Time - The number of hours to set for charging the batteries
  • Maximum Priority Channels - sets the maximum priority channel numbers that are scanned during one priority scan interrupt. If there are more priority channels than the value you select, the channels are divided into more than one group and the scanner scans each group in turn. For example, if you set the maximum channels to 20 and there are 100 priority channels, the scanner checks those 100 channels in groups of 20 and takes a total of 5 intervals to complete the priority scan.
  • Priority Interval Time - sets how often the scanner will check the priority channels.

LCD

  • Mode 1 (Channel Data)
    • If Enable Unit ID is on, the scanner will alternate the current channel information and the Unit ID information in Line 2 of the display
  • Mode 2 (Frequency)
    • If Enable Unit ID is on, the scanner will alternate the current channel information and the Unit ID information in Line 2 of the display
  • Mode 3 (XT Trunking Indicator)
    • If Enable Unit ID is on, the Unit ID will show up on Line 3 of the display
  • Enable Active Channel Display Mode
  • Flip Display Upside Down

This data comes from the Easier to Read manuals and the Uniden TWiki
Proceed to the Close Call article
Return to the Setup Scanner Options article
Return to the FreeScan User Guide