Actions

Difference between revisions of "Object Oriented Scanners Issues"

From The RadioReference Wiki

m
Line 1: Line 1:
 
Please put all information on operating issues (except [[Object Oriented Scanners Overload Issues|overloading issues]], which has its own article) and how to resolve them here. Be sure to keep the category and return links as the last 2 lines in this article.
 
Please put all information on operating issues (except [[Object Oriented Scanners Overload Issues|overloading issues]], which has its own article) and how to resolve them here. Be sure to keep the category and return links as the last 2 lines in this article.
  
*Default scanlist - PRO-197 / PSR-600 - The default scanlist is 01. If you're creating objects manually but can't find them, check scanlist 01.
+
This page applies to the following scanners (unless otherwise noted):<br>
 +
'''Pro-106/197, Pro-107/18, PSR-500/600, PSR-700/800'''
  
*Search Steps - PRO-197 / PSR-600 - Search steps or increments are not definable by the user. GRE says this feature is often requested.
+
*Default scanlist - The default scanlist is 01. If you're creating objects manually but can't find them, check scanlist 01.
  
*TSYS / TGRP objects - PRO-197 / PSR-600 - A TGRP object must be created before a TSYS. If the NEW / TGRP buttons are pressed too quickly, a blank TGRP is created in the default scanlist. Press the buttons slowly.
+
*Search Steps - Search steps or increments are not definable by the user. Try changing the BandPlan setting to Canada for 5 kHz steps. GRE says this feature is often requested.
 +
 
 +
*TSYS / TGRP objects - (Pro-106/197 and PSR-500/600 only) A TGRP object must be created before a TSYS. If the NEW / TGRP buttons are pressed too quickly, a blank TGRP is created in the default scanlist. Press the buttons slowly.
  
 
*"Nothing Enabled" error:
 
*"Nothing Enabled" error:
Line 11: Line 14:
 
**Scanlists are enabled but empty. Create and/or associate objects with scanlists.
 
**Scanlists are enabled but empty. Create and/or associate objects with scanlists.
 
**Scanlist is enabled but all objects in scanlist are locked out. Unlock some objects.
 
**Scanlist is enabled but all objects in scanlist are locked out. Unlock some objects.
**Note - For a TSYS it's possible to lock out a wildcard talkgroup AND the TSYS itself, which will cause "Nothing Enabled" until both are unlocked.  
+
**Note - (Pro-106/197 and PSR-500/600 only) For a TSYS it's possible to lock out a wildcard talkgroup AND the TSYS itself, which will cause "Nothing Enabled" until both are unlocked.  
  
*If you find the Signal Stalker is consistently off frequency;
+
*If you find the Signal Stalker/Spectrum Sweeper is consistently off frequency (Pro-106/197 and PSR-500/600 only);
 
**Prog Func F3 Down To Zeromatic Values  
 
**Prog Func F3 Down To Zeromatic Values  
 
**Enter The following 8 Numbers In Order
 
**Enter The following 8 Numbers In Order
Line 24: Line 27:
 
  150
 
  150
 
  530
 
  530
 
 
  
  

Revision as of 10:08, 29 December 2012

Please put all information on operating issues (except overloading issues, which has its own article) and how to resolve them here. Be sure to keep the category and return links as the last 2 lines in this article.

This page applies to the following scanners (unless otherwise noted):
Pro-106/197, Pro-107/18, PSR-500/600, PSR-700/800

  • Default scanlist - The default scanlist is 01. If you're creating objects manually but can't find them, check scanlist 01.
  • Search Steps - Search steps or increments are not definable by the user. Try changing the BandPlan setting to Canada for 5 kHz steps. GRE says this feature is often requested.
  • TSYS / TGRP objects - (Pro-106/197 and PSR-500/600 only) A TGRP object must be created before a TSYS. If the NEW / TGRP buttons are pressed too quickly, a blank TGRP is created in the default scanlist. Press the buttons slowly.
  • "Nothing Enabled" error:
    • No scanlists are enabled. Turn on one or more scanlists.
    • Scanlists are enabled but empty. Create and/or associate objects with scanlists.
    • Scanlist is enabled but all objects in scanlist are locked out. Unlock some objects.
    • Note - (Pro-106/197 and PSR-500/600 only) For a TSYS it's possible to lock out a wildcard talkgroup AND the TSYS itself, which will cause "Nothing Enabled" until both are unlocked.
  • If you find the Signal Stalker/Spectrum Sweeper is consistently off frequency (Pro-106/197 and PSR-500/600 only);
    • Prog Func F3 Down To Zeromatic Values
    • Enter The following 8 Numbers In Order
170
480
150
530
170
480
150
530





Return to the GRE/RS Object Oriented Scanners FAQ