Please put all information on operating issues (except overloading issues, which has its own article) and how to resolve them here. Be sure to keep the category and return links as the last 2 lines in this article.

  • Default scanlist - PRO-197 / PSR-600 - The default scanlist is 01. If you're creating objects manually but can't find them, check scanlist 01.
  • Search Steps - PRO-197 / PSR-600 - Search steps or increments are not definable by the user. GRE says this feature is often requested.
  • TSYS / TGRP objects - PRO-197 / PSR-600 - A TGRP object must be created before a TSYS. If the NEW / TGRP buttons are pressed too quickly, a blank TGRP is created in the default scanlist. Press the buttons slowly.
  • "Nothing Enabled" error:
    • No scanlists are enabled. Turn on one or more scanlists.
    • Scanlists are enabled but empty. Create and/or associate objects with scanlists.
    • Scanlist is enabled but all objects in scanlist are locked out. Unlock some objects.
    • Note - For a TSYS it's possible to lock out a wildcard talkgroup AND the TSYS itself, which will cause "Nothing Enabled" until both are unlocked.
  • If you find the Signal Stalker is consistently off frequency;
    • Prog Func F3 Down To Zeromatic Values
    • Enter The following 8 Numbers In Order
170
480
150
530
170
480
150
530






Return to the GRE/RS Object Oriented Scanners FAQ