Actions

Difference between revisions of "Saskatchewan P25 and Trunktrackers"

From The RadioReference Wiki

m
Line 155: Line 155:
 
|}
 
|}
  
 +
 +
==Update January 2010: Reports have come in from many Pro96 users stating that their scanners will not trunk this system at all.==
  
 
<small>[http://wiki.radioreference.comindex.php?title=Saskatchewan_P25_and_Trunktrackers?action=purge Refresh] this page from the latest database entry</small>  
 
<small>[http://wiki.radioreference.comindex.php?title=Saskatchewan_P25_and_Trunktrackers?action=purge Refresh] this page from the latest database entry</small>  

Revision as of 10:31, 30 January 2010

Trunktracker Information

  • These M/A-COM P25ip Systems control channels use Multi-Block Messaging Operation for Explicit Group/Voice Channel Grants.
  • All tower sites share the same system ID of HEX#00A/DEC#10 and the same WACN of HEX#0000A/DEC#10 and the same NAC of 10.
  • These scanners will decode and trunktrack these systems, but older models may not;


The Radio Shack Pro-96/Pro-2096 can not decode the multi-block messages sent by the control channel so they may only trunk a single channel on a system. The BC250D and BC785D can not decode the 9600-baud rate control channel so it will not trunktrack these systems. The scanner must be able to operate in P25 9600 baud Explicit Mode.

Pro-96/2096 Trunking Information

  • To trunktrack these systems the Pro-96/Pro-2096 must have custom extended tables programmed with Win96 software. These Radio Shack scanner models require a different set of custom trunking tables for every tower site in the system unless a site is used over again at another location in the Province. Channel #1 is 138.0150 and the last channel #100 is 139.5000. With this information the custom tables can be programmed for any tower site in the system.
  • Tx Frequency Range 138-139.5000 MHz
  • Rx Frequency Range 141-142.5000 MHz
  • Base = 138.000 in all cases
  • Step = 15.0 in all cases

Pro-96/2096 Custom Extended Tables

Site #001 Regina Downtown

SiteNameFreqs     
10-005 (A-5) Regina - SaskPower Head Office138.510000c 138.675000c 138.795000c 139.035000c 139.140000c 139.245000c


Slot Number Low Channel High Channel Offset
00 00 34 00
01 35 45 35
02 46 53 46
03 54 69 54
04 70 76 70
05 77 83 77


Site #002 Pilot Butte

SiteNameFreqs   
10-002 (A-2) Alsask138.450000a 138.555000a 138.780000c 139.275000a


Slot Number Low Channel High Channel Offset
00 00 35 00
01 36 58 36
02 59 66 59


Site #071 Fort Qu'Appelle

SiteNameFreqs   
10-071 (A-47) Fort Qu'Appelle138.240000a 138.465000a 139.095000c 139.305000a


Slot Number Low Channel High Channel Offset
00 00 31 00
01 32 73 32
02 74 87 74


Site #081 Moose Jaw

SiteNameFreqs   
10-181 (A-B5) Pasqua138.030000c 138.210000c 138.360000c 138.720000c


Slot Number Low Channel High Channel Offset
00 00 02 00
01 03 14 03
02 15 24 15
03 25 56 25
04 57 64 57


Update January 2010: Reports have come in from many Pro96 users stating that their scanners will not trunk this system at all.

Refresh this page from the latest database entry