Actions

Difference between revisions of "Software Support for Uniden Rebanding"

From The RadioReference Wiki

Line 53: Line 53:
 
   
 
   
 
==FreeScan==
 
==FreeScan==
[[Image:FS rebanding v.8.JPG|thumb|right|Site screen with bandplan]]
+
<gallery>
 +
Image:FS rebanding v.8.JPG|Site screen with bandplan  
 +
</gallery>
 
To access this screen, change the site type to '''Mot Custom/Reband'''. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table.
 
To access this screen, change the site type to '''Mot Custom/Reband'''. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table.
 +
 +
==ProScan==
 +
* '''NOTE:''' Although ProScan supports the BC250/785, rebanding is '''not''' supported in these models.
 +
===BC296/796D===
 +
<gallery>
 +
Image:ProScan CBank editor.JPG|figure 1
 +
Image:ProScan CBank Tbank.JPG|figure 2
 +
</gallery>
 +
#On the 'Database' Row, click on 'Trunk Bank Settings' (figure 1)
 +
#Fill in the values as shown (figure 2)
 +
===DMA Scanners===
 +
<gallery>
 +
Image:ProScan DMA Systems toolbar.JPG|figure 1
 +
Image:ProScan DMA System Type.JPG|figure 2
 +
Image:ProScan DMA System screen.JPG|figure 3
 +
Image:ProScan DMA band plan.JPG|figure 4
 +
</gallery>
 +
#Below the Systems tab, hit 'Add' (figure 1)
 +
#On the System pulldown, select 'MOT 800 Mhz Custom' (figure 2)
 +
#In the System tree, click on the system name. Figure 3 results (partially shown to conserve space)
 +
#Click on the 'Band Plan' button
 +
#Fill in the data as shown (figure 4)
 +
 +
  
 
Return to the [[Uniden DMA FAQ]]
 
Return to the [[Uniden DMA FAQ]]

Revision as of 12:56, 9 August 2009

Please use this article to document how to enter the Rebanding changes outlined below in the various software packages that support Uniden scanners.

Band Plan Base Freq (lower) Base Freq (upper) Offset Polarity Spacing
1 851.025 854.000 440 + 25 khz
2 851.0125 868.9875 0 + 25 khz

As of this writing, the following software packages are known to support rebanding.

  • BC246.TCL for the BC246- Macs, Unix and Windows (TCL/TK) support - freeware
  • BuTel Software
    • ARC396
    • ARC996
    • ARC246 (as of version 3.1)
    • ARC15 (as of version 3)
Unknown Rebanding Support

Additional Information requested...

  • BuTel Software
    • ARC330
    • ARC250 (for the BC296 and BC796 only)
    • ARC898
    • ARC8
    • ARC-XT (for the Uniden XT DMA scanners)
  • Trunkstar All Products

FreeScan

To access this screen, change the site type to Mot Custom/Reband. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table.

ProScan

  • NOTE: Although ProScan supports the BC250/785, rebanding is not supported in these models.

BC296/796D

  1. On the 'Database' Row, click on 'Trunk Bank Settings' (figure 1)
  2. Fill in the values as shown (figure 2)

DMA Scanners

  1. Below the Systems tab, hit 'Add' (figure 1)
  2. On the System pulldown, select 'MOT 800 Mhz Custom' (figure 2)
  3. In the System tree, click on the system name. Figure 3 results (partially shown to conserve space)
  4. Click on the 'Band Plan' button
  5. Fill in the data as shown (figure 4)


Return to the Uniden DMA FAQ