Difference between revisions of "Software Support for Uniden Rebanding"
From The RadioReference Wiki
Line 53: | Line 53: | ||
==FreeScan== | ==FreeScan== | ||
− | + | <gallery> | |
+ | Image:FS rebanding v.8.JPG|Site screen with bandplan | ||
+ | </gallery> | ||
To access this screen, change the site type to '''Mot Custom/Reband'''. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table. | To access this screen, change the site type to '''Mot Custom/Reband'''. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table. | ||
+ | |||
+ | ==ProScan== | ||
+ | * '''NOTE:''' Although ProScan supports the BC250/785, rebanding is '''not''' supported in these models. | ||
+ | ===BC296/796D=== | ||
+ | <gallery> | ||
+ | Image:ProScan CBank editor.JPG|figure 1 | ||
+ | Image:ProScan CBank Tbank.JPG|figure 2 | ||
+ | </gallery> | ||
+ | #On the 'Database' Row, click on 'Trunk Bank Settings' (figure 1) | ||
+ | #Fill in the values as shown (figure 2) | ||
+ | ===DMA Scanners=== | ||
+ | <gallery> | ||
+ | Image:ProScan DMA Systems toolbar.JPG|figure 1 | ||
+ | Image:ProScan DMA System Type.JPG|figure 2 | ||
+ | Image:ProScan DMA System screen.JPG|figure 3 | ||
+ | Image:ProScan DMA band plan.JPG|figure 4 | ||
+ | </gallery> | ||
+ | #Below the Systems tab, hit 'Add' (figure 1) | ||
+ | #On the System pulldown, select 'MOT 800 Mhz Custom' (figure 2) | ||
+ | #In the System tree, click on the system name. Figure 3 results (partially shown to conserve space) | ||
+ | #Click on the 'Band Plan' button | ||
+ | #Fill in the data as shown (figure 4) | ||
+ | |||
+ | |||
Return to the [[Uniden DMA FAQ]] | Return to the [[Uniden DMA FAQ]] |
Revision as of 12:56, 9 August 2009
Please use this article to document how to enter the Rebanding changes outlined below in the various software packages that support Uniden scanners.
Band Plan | Base Freq (lower) | Base Freq (upper) | Offset | Polarity | Spacing |
---|---|---|---|---|---|
1 | 851.025 | 854.000 | 440 | + | 25 khz |
2 | 851.0125 | 868.9875 | 0 | + | 25 khz |
As of this writing, the following software packages are known to support rebanding.
- BC246.TCL for the BC246- Macs, Unix and Windows (TCL/TK) support - freeware
- FreeScan (Freeware)
- BuTel Software
- ARC396
- ARC996
- ARC246 (as of version 3.1)
- ARC15 (as of version 3)
- Unknown Rebanding Support
Additional Information requested...
- BuTel Software
- ARC330
- ARC250 (for the BC296 and BC796 only)
- ARC898
- ARC8
- ARC-XT (for the Uniden XT DMA scanners)
- Trunkstar All Products
FreeScan
To access this screen, change the site type to Mot Custom/Reband. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table.
ProScan
- NOTE: Although ProScan supports the BC250/785, rebanding is not supported in these models.
BC296/796D
- On the 'Database' Row, click on 'Trunk Bank Settings' (figure 1)
- Fill in the values as shown (figure 2)
DMA Scanners
- Below the Systems tab, hit 'Add' (figure 1)
- On the System pulldown, select 'MOT 800 Mhz Custom' (figure 2)
- In the System tree, click on the system name. Figure 3 results (partially shown to conserve space)
- Click on the 'Band Plan' button
- Fill in the data as shown (figure 4)
Return to the Uniden DMA FAQ