Difference between revisions of "Software Support for Uniden Rebanding"
From The RadioReference Wiki
Line 39: | Line 39: | ||
* [http://www.butelsoftware.com BuTel Software] | * [http://www.butelsoftware.com BuTel Software] | ||
+ | ** ARC-XT (for the Uniden XT DMA scanners) | ||
** ARC396 | ** ARC396 | ||
** ARC996 | ** ARC996 | ||
** ARC246 ''(as of version 3.1)'' | ** ARC246 ''(as of version 3.1)'' | ||
** ARC15 ''(as of version 3)'' | ** ARC15 ''(as of version 3)'' | ||
+ | ** ARC330 | ||
; Unknown Rebanding Support | ; Unknown Rebanding Support | ||
Line 48: | Line 50: | ||
<br> | <br> | ||
* [http://www.butelsoftware.com BuTel Software] | * [http://www.butelsoftware.com BuTel Software] | ||
− | + | ** ARC250 ''(due in Q4)'' | |
− | ** ARC250 ''( | + | ** ARC898 ''(due in Q4)'' |
− | ** ARC898 | + | ** ARC8 ''(due in Q4)'' |
− | ** ARC8 | + | * [http://www.scanstar.com Trunkstar] All Products |
− | + | ||
− | * [http://www.scanstar.com Trunkstar] All Products | ||
− | |||
==FreeScan== | ==FreeScan== | ||
<gallery> | <gallery> |
Revision as of 12:30, 13 August 2009
Please use this article to document how to enter the Rebanding changes outlined below in the various software packages that support Uniden scanners.
General
- XT version scanners already have the firmware updates to support rebanding. Non-XT scanners will need to undergo the appropriate firmware updates. These updates are listed here
Band Plan | Base Freq (lower) | Base Freq (upper) | Offset | Polarity | Spacing |
---|---|---|---|---|---|
1 | 851.025 | 854.000 | 440 | + | 25 khz |
2 | 851.0125 | 868.9875 | 0 | + | 25 khz |
As of this writing, the following software packages are known to support rebanding.
- BC246.TCL for the BC246- Macs, Unix and Windows (TCL/TK) support - freeware
- FreeScan (Freeware)
- BuTel Software
- ARC-XT (for the Uniden XT DMA scanners)
- ARC396
- ARC996
- ARC246 (as of version 3.1)
- ARC15 (as of version 3)
- ARC330
- Unknown Rebanding Support
Additional Information requested...
- BuTel Software
- ARC250 (due in Q4)
- ARC898 (due in Q4)
- ARC8 (due in Q4)
- Trunkstar All Products
FreeScan
To access this screen, change the site type to Mot Custom/Reband. If you are using the RR Trunk Import, and the rebanded flag has been turned on in the database, FreeScan automatically adds the appropriate values into the table.
ProScan
- NOTE: Although ProScan supports the BC250/785, rebanding is not supported in these models.
BC296/796D
- On the 'Database' Row, click on 'Trunk Bank Settings' (figure 1)
- Fill in the values as shown (figure 2)
DMA Scanners
- Below the Systems tab, hit 'Add' (figure 1)
- On the System pulldown, select 'MOT 800 Mhz Custom' (figure 2)
- In the System tree, click on the system name. Figure 3 results (partially shown to conserve space)
- Click on the 'Band Plan' button
- Fill in the data as shown (figure 4)
Return to the Uniden DMA FAQ