Actions

Difference between revisions of "Uniden Multi-Site Trunking"

From The RadioReference Wiki

m (updated categories)
m
Line 1: Line 1:
This feature is implemented in the [[BCT15]], [[BCD996T]] and all XT branded Uniden trunking scanners.
+
This feature is implemented in the [[BCT15]], [[BCD996T]], BCDx96XT, and P2, branded Uniden trunking scanners.
  
 
Some Motorola and [[EDACS]] wide coverage systems use multiple system sites that are linked together to provide extended area coverage. Each site operates on its own set of frequencies, but share common talk group channels with all other sites in the system.
 
Some Motorola and [[EDACS]] wide coverage systems use multiple system sites that are linked together to provide extended area coverage. Each site operates on its own set of frequencies, but share common talk group channels with all other sites in the system.
Line 20: Line 20:
 
               Frequencies
 
               Frequencies
 
               Other Attributes
 
               Other Attributes
          Channel Group
+
                    Channel Group
              Channel Group Attributes
+
                        Channel Group Attributes
              Channel
+
                        Channel
                    Channel Attributes
+
                              Channel Attributes
              Channel
+
                        Channel
                    Channel Attributes
+
                              Channel Attributes
          Channel Group
+
                    Channel Group
              Channel Group Attributes
+
                        Channel Group Attributes
              Channel
+
                        Channel
                    Channel Attributes
+
                              Channel Attributes
              Channel
+
                        Channel
                    Channel Attributes
+
                              Channel Attributes
  
 
The System tag is never displayed, but makes the system easy to find for programming updates.
 
The System tag is never displayed, but makes the system easy to find for programming updates.

Revision as of 14:34, 2 April 2016

This feature is implemented in the BCT15, BCD996T, BCDx96XT, and P2, branded Uniden trunking scanners.

Some Motorola and EDACS wide coverage systems use multiple system sites that are linked together to provide extended area coverage. Each site operates on its own set of frequencies, but share common talk group channels with all other sites in the system.

With the initial implementation of dynamic memory, each site needed to be entered as its own system, so all talk group channels had to be duplicated for each site. This resulted in more complexity in programming as well as more memory usage.

With this method, you define a system, one or more sites for the system with its respective frequencies, and then the talk group IDs for the system. All IDs are shared among all sites.

Normally, a site will only carry traffic for talk groups that have at least one subscriber unit (mobile radio) affiliated with it.

Here’s an outline of a Multi-Site System:

    System
         System Attributes
         Site
              Frequencies
              Other Attributes
         Site
              Frequencies
              Other Attributes
                    Channel Group
                        Channel Group Attributes
                        Channel
                             Channel Attributes
                        Channel
                             Channel Attributes
                   Channel Group
                        Channel Group Attributes
                        Channel
                             Channel Attributes
                        Channel
                             Channel Attributes

The System tag is never displayed, but makes the system easy to find for programming updates.

Primary Site attributes include:

  • Site Name
  • Site Quick Key: Equivalent to the System Quick Key; turns the site on/off for scanning.
  • Site Startup Key: Allows you to turn on the scanner with certain sites enabled to scan different areas.
  • Site Frequencies
  • Site Hold Time: Sets how long the scanner will monitor the site.
  • Site Location: Allows you to set the scanner to scan by location and range if you use the scanner with a GPS unit attached.


Return to the Uniden DMA FAQ