Difference between revisions of "Uniden Scanners"
From The RadioReference Wiki
m (remove duplicate entry) |
|||
(14 intermediate revisions by 3 users not shown) | |||
Line 26: | Line 26: | ||
| 2019 | | 2019 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital | + | | Digital - '''Trunking:Motorola,EDACS,LTR, Digital:P25(Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN ''' / Full US Database Load / GPS |
| 384Z | | 384Z | ||
|- | |- | ||
Line 33: | Line 33: | ||
| 2018 | | 2018 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital | + | | Digital - '''Trunking: Motorola,EDACS,LTR, Digital:P25(Phase 1+2)''' / GPS / CB - PreProgrammed for Police/Fire/EMS/DeptofTrans/Highway Patrol - Beartracker Warning System / Unable to program user freq. / Updated US Database weekly. |
| 378Z | | 378Z | ||
|- | |- | ||
Line 40: | Line 40: | ||
| 2015 03 | | 2015 03 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital | + | | Digital - '''Trunking: Motorola,EDACS,LTR, Digital:P25(Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN''' / GPS |
| 378Z | | 378Z | ||
|- | |- | ||
Line 47: | Line 47: | ||
| 2014 01 | | 2014 01 | ||
| style="color:green" | Yes-Download from RRDB | | style="color:green" | Yes-Download from RRDB | ||
− | | Digital | + | | Digital - '''Trunking:Motorola,EDACS,LTR,Digital: P25 (Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN''' - Full US Database Load / GPS |
| 375Z | | 375Z | ||
|- | |- | ||
Line 54: | Line 54: | ||
| 2014 11 | | 2014 11 | ||
| style="color:green" | Yes-Download from RRDB | | style="color:green" | Yes-Download from RRDB | ||
− | | Digital | + | | Digital - '''Trunking: Motorola, EDACS, LTR, Digital: P25 (Phase 1 and 2)''' - Full US Database Load / GPS |
| 377Z | | 377Z | ||
+ | |- | ||
+ | | [[BC-355N]] | ||
+ | | [[File:Bearcat BC355n.jpg|300px|thumb|center]] | ||
+ | | 2012 | ||
+ | | style="color:green" | Yes-Download from RRDB | ||
+ | | No Trunking Mobile - Service Search 25-54Mhz/108-174Mhz/406-512Mhz/806-956Mhz (no cell) | ||
+ | | | ||
|- | |- | ||
| [[HomePatrol-1]] | | [[HomePatrol-1]] | ||
Line 61: | Line 68: | ||
| 2010 11 | | 2010 11 | ||
| style="color:green" | Yes-Download from RRDB | | style="color:green" | Yes-Download from RRDB | ||
− | | Digital | + | | Digital- '''Trunking: Motorola, EDACS, LTR, Digital: P25 (Phase 1)''' / Full US Database Load / GPS |
| 363Z | | 363Z | ||
|- | |- | ||
Line 68: | Line 75: | ||
| 2009 08 | | 2009 08 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | | + | | Analog - '''Trunking: Motorola, EDACS, LTR''' / GPS / SAME / 25-512Mhz/758-823Mhz/894-960Mhz/1240-1300Mhz |
| 361Z | | 361Z | ||
|- | |- | ||
Line 75: | Line 82: | ||
| 2009 07 | | 2009 07 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital | + | | Digital - '''Trunking:Motorola, EDACS, LTR, DigitalP25 (Phase 1)''' / GPS / 25,000 Channels /100ch sec scan / 25-512Mhz/758-823Mhz/849-868Mhz/894-960Mhz/1240-1300Mhz |
| 360Z | | 360Z | ||
|- | |- | ||
Line 82: | Line 89: | ||
| 2008 02 | | 2008 02 | ||
| style="color:green" | N/A | | style="color:green" | N/A | ||
− | | | + | | Analog- '''Trunking: Motorola, EDACS, LTR''' Channels: 6,000 / GPS / 100ch sec scan / 25-512Mhz/806-960Mhz (no cell)/1240-1300Mhz. |
| | | | ||
|- | |- | ||
Line 96: | Line 103: | ||
| 2006 06 | | 2006 06 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | | + | | Analog- '''Trunking: Motorola, EDACS, LTR''' / Channels: 2,500 / 100ch sec scan / 25-512Mhz/764-776Mhz/794-956Mhz (no cell)/1240-1300Mhz |
| 336Z | | 336Z | ||
|- | |- | ||
Line 103: | Line 110: | ||
| 2006 06 | | 2006 06 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking-AM/FM Clock Radio / SAME - 25-54Mhz/108-174Mhz/225-512Mhz/806-956Mhz (no cell)/520-1720Khz(AM)/88-108Mhz(FM) |
| 338Z | | 338Z | ||
|- | |- | ||
Line 110: | Line 117: | ||
| 2006 05 | | 2006 05 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital | + | | Digital- '''Trunking: Motorola, EDACS, LTR, Digital: P25 (Phase 1)''' Channels 25,000/ GPS / 25-512Mhz/758-823Mhz/849-868Mhz/894-960Mhz/1240-1300Mhz |
| 335Z | | 335Z | ||
|- | |- | ||
Line 117: | Line 124: | ||
| 2006 04 | | 2006 04 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking- Clock Radio -Service Search / 100 Channel AM/FM/29-54Mhz/108-174Mhz/406-512Mhz/ |
| 337Z | | 337Z | ||
|- | |- | ||
Line 124: | Line 131: | ||
| 2004 08 | | 2004 08 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | | + | | Analog- '''Trunking: Motorola, EDACS, LTR''' - SAME / 25-54Mhz/108-174Mhz/216-512Mhz/806-956Mhz (no cell) |
| 322Z | | 322Z | ||
|- | |- | ||
Line 131: | Line 138: | ||
| 2004 02 | | 2004 02 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | | + | | Analog- '''Trunking: Motorola, EDACS, LTR''' - Channels 250 / BearTracker Warning Sys / 25-54Mhz/108-174Mhz/400-512Mhz/806-956Mhz (no cell) |
| 318Z | | 318Z | ||
|- | |- | ||
Line 138: | Line 145: | ||
| 2004 | | 2004 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - Channels 100 user / 100ch sec scan / 25-54Mhz/108-174Mhz/406-512Mhz/806-956Mhz (no cell) |
| 317Z | | 317Z | ||
|- | |- | ||
Line 145: | Line 152: | ||
| 2003 12 | | 2003 12 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital | + | | Digital- '''Trunking:Motorola, EDACS, LTR, Digital: P25 (Phase 1)''' - SAME/Channels 1,000/ 25-512Mhz/849-868Mhz/894-956Mhz/1240-1300Mhz |
| 320Z | | 320Z | ||
|- | |- | ||
Line 152: | Line 159: | ||
| 2003 02 | | 2003 02 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | | + | | Analog- '''Trunking: Motorola, EDACS, LTR (w/BC25i card) Motorola Mixed mode 3600 baud'''- SAME/Channels 1,000/ 25-512Mhz/849-868Mhz/894-956Mhz/1240-1300Mhz |
| 316Z | | 316Z | ||
|- | |- | ||
Line 159: | Line 166: | ||
| 2000 | | 2000 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | | + | | Analog- '''Trunking: Motorola, EDACS, LTR''' - SAME / Channels 500 / 100ch sec scan/ 25-512Mhza/806-956Mhz (no cell)/1240-1300Mhz. |
| | | | ||
|- | |- | ||
Line 166: | Line 173: | ||
| 1999 | | 1999 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | | + | | No Trunking Clock Radio / SAME - 100 Channel - AM/FM/25-174Mhz/406-512Mhz/806-956Mhz (no cell) |
| | | | ||
|- | |- | ||
Line 173: | Line 180: | ||
| 1999 | | 1999 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | | + | | No Trunking Clock Radio / SAME - 50 Channel - AM/FM/29-54Mhz/137-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 180: | Line 187: | ||
| 1997 09 | | 1997 09 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | | + | | Analog- '''Trunking: Motorola I/II''' - Channels: 300 /Scan 100 Ch sec/ 29-54Mhz/108-174Mhz/216-512Mhz/806-956Mhz (no cell) |
+ | | | ||
+ | |- | ||
+ | | [[BCT-12 StormTracker]] | ||
+ | | [[File:Bearcat BCT-12 Storm.jpg|250px|thumb|center]] | ||
+ | | 1997 | ||
+ | | N/A | ||
+ | | No Trunking Mobile/Pre-program for 50 States/ Bearcat Warning System/37-46Mhz/138-172Mhz/423-508Mhz/806-868Mhz | ||
+ | | | ||
+ | |- | ||
+ | | [[BCT-12]] | ||
+ | | [[File:Bearcat BCT-12.jpg|250px|thumb|center]] | ||
+ | | 1996 | ||
+ | | N/A | ||
+ | | No Trunking Mobile/Pre-program for 50 States/ Bearcat Warning System/37-46Mhz/138-172Mhz/423-508Mhz/806-868Mhz | ||
+ | | | ||
+ | |- | ||
+ | | [[BC-760XLT]] | ||
+ | | [[File:Bearcat-BC-760xlt.jpg|250px|thumb|center]] | ||
+ | | 1995 | ||
+ | | N/A | ||
+ | | No Trunking -100 Channel/Mobile/Pre-program / - 29-54Mhz/118-174Mhz/406-512Mhz/806-956Mhz | ||
+ | | | ||
+ | |- | ||
+ | | [[BC-590XLT]] | ||
+ | | [[File:Bearcat-BC-590XLT.jpg|250px|thumb|center]] | ||
+ | | 1995 | ||
+ | | N/A | ||
+ | | No Trunking -100 Channel /Mobile/Pre-Progrma/ 29-54Mhz/118-174Mhz/406-512Mhz | ||
+ | | | ||
+ | |- | ||
+ | | [[BCT-10]] | ||
+ | | [[File:Bearcat BCT-10.jpg|250px|thumb|center]] | ||
+ | | 1995 | ||
+ | | N/A | ||
+ | | No Trunking -Mobile/Pre-program for 50 States/ Bearcat Warning System/37-46Mhz/138-172Mhz/423-508Mhz | ||
| | | | ||
|- | |- | ||
Line 187: | Line 229: | ||
| 1994? | | 1994? | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - Mobile - BearTracker Alert System / 100 Channel CB/29-54Mhz/108-174Mhz/406-512Mhz/806-956Mhz |
+ | | | ||
+ | |- | ||
+ | | [[BC-9000XLT]] | ||
+ | | [[File:Bearcat-BC-9000XLT.jpg|250px|thumb|center]] | ||
+ | | 1994 | ||
+ | | N/A | ||
+ | | No Trunking - 500 Channel / Alphanumeric - 25-54Mhz/108-174Mhz/216-512Mhz/806-956Mhz | ||
| | | | ||
|- | |- | ||
Line 194: | Line 243: | ||
| 1992 | | 1992 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 16 Channel / 2 Digit Display - 29-54Mhz/108-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 201: | Line 250: | ||
| 1989 | | 1989 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking- Mobile -Pre-Programmed for 50 states / Beartracker Warning System - 29-54Mhz/118-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 208: | Line 257: | ||
| 1989? | | 1989? | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 100 Channel - 29-54Mhz/118-174Mhz/406-512Mhz/806-956Mhz |
| | | | ||
|- | |- | ||
Line 215: | Line 264: | ||
| 1987 | | 1987 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking -Mobile -Pre-Programmed for 50 states - 29-54Mhz/118-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 222: | Line 271: | ||
| 1987 | | 1987 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 16 Channel - 29-54Mhz/118-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 229: | Line 278: | ||
| 1987 | | 1987 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking- 40 channels - 29-54Mhz/118-174Mhz/416-512Mhz. |
| | | | ||
|- | |- | ||
Line 236: | Line 285: | ||
| 1986 | | 1986 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 16 Channel - 66-88Mhz/118-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 244: | Line 293: | ||
| 1985 | | 1985 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 20 Channel - 29-54Mhz/108-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 251: | Line 300: | ||
| 1983 | | 1983 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - Mobile - Channels - 10 Channel / 29-54Mhz/136-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 258: | Line 307: | ||
| 1982 | | 1982 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 16 Channel / 30-50Mhz/138-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 265: | Line 314: | ||
| 1982 | | 1982 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - Channels - 16 Channel / 32-50Mhz/144-174Mhz/450-512Mhz |
| | | | ||
|- | |- | ||
Line 272: | Line 321: | ||
| 1981 | | 1981 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking- Mobile - Channels - 50 user / 29-54Mhz/137-174Mhz/406-512Mhz |
| | | | ||
|- | |- | ||
Line 279: | Line 328: | ||
| 1979 | | 1979 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 50 channels 30-50Mhz/108-136Mhz/144-174Mhz/420-512Mhz. |
| | | | ||
|- | |- | ||
Line 287: | Line 336: | ||
| 1977 | | 1977 | ||
| N/A | | N/A | ||
− | | | + | | No Trunking - 10 channels - 32-50Mhz/146-174Mhz/416-512Mhz. |
| | | | ||
|- | |- | ||
Line 353: | Line 402: | ||
| 2018 | | 2018 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked | + | | '''Digital - Motorola, EDACS, LTR, P25 (Phase 1+2),(with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN''' |
| 383Z | | 383Z | ||
|- | |- | ||
Line 360: | Line 409: | ||
| Apr 2015 | | Apr 2015 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked | + | | '''Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN''' |
| 379Z | | 379Z | ||
|- | |- | ||
Line 367: | Line 416: | ||
| Jan 2014 | | Jan 2014 | ||
| style="color:green" | Yes-Download from RRDB | | style="color:green" | Yes-Download from RRDB | ||
− | | Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked | + | | '''Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN''' |
| 376Z | | 376Z | ||
|- | |- | ||
Line 374: | Line 423: | ||
| 2019 | | 2019 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| 385Z | | 385Z | ||
|- | |- | ||
Line 381: | Line 430: | ||
| 2013 | | 2013 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| 372Z | | 372Z | ||
|- | |- | ||
Line 388: | Line 437: | ||
| 2012 | | 2012 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| 370Z | | 370Z | ||
|- | |- | ||
Line 395: | Line 444: | ||
| 2009 | | 2009 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Analog - Motorola, EDACS, LTR | + | | Analog - '''Trunking: Motorola, EDACS, LTR''' |
| 358Z | | 358Z | ||
|- | |- | ||
Line 402: | Line 451: | ||
| 2009 | | 2009 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital - Motorola, EDACS, LTR, P25 (Phase 1) | + | | '''Digital - Motorola, EDACS, LTR, P25 (Phase 1)''' |
| 359Z | | 359Z | ||
|- | |- | ||
Line 409: | Line 458: | ||
| 2006 | | 2006 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 416: | Line 465: | ||
| 2006 | | 2006 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| 323Z | | 323Z | ||
|- | |- | ||
Line 423: | Line 472: | ||
| 2005 | | 2005 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital - Motorola, EDACS, LTR, P25 (Phase 1) | + | | '''Digital - Motorola, EDACS, LTR, P25 (Phase 1)''' |
| 328Z | | 328Z | ||
|- | |- | ||
Line 430: | Line 479: | ||
| 2005-2007 | | 2005-2007 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Analog - Motorola, EDACS, LTR | + | | Analog - '''Trunking: Motorola, EDACS, LTR''' |
| 330Z | | 330Z | ||
|- | |- | ||
Line 437: | Line 486: | ||
| ? | | ? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 444: | Line 493: | ||
| 2005 | | 2005 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 451: | Line 500: | ||
| 2004 | | 2004 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Analog - Motorola, EDACS, LTR | + | | Analog - '''Trunking: Motorola, EDACS, LTR''' |
| 326Z | | 326Z | ||
|- | |- | ||
Line 458: | Line 507: | ||
| 2004? | | 2004? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 465: | Line 514: | ||
| Early 2004 | | Early 2004 | ||
| style="color:green" | Yes | | style="color:green" | Yes | ||
− | | Digital - Motorola, EDACS, LTR, P25 (Phase 1) | + | | '''Digital - Motorola, EDACS, LTR, P25 (Phase 1)''' |
| 319Z | | 319Z | ||
|- | |- | ||
Line 472: | Line 521: | ||
| 2004 (China made) or 2011 (Viet Nam made) | | 2004 (China made) or 2011 (Viet Nam made) | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| 323Z (China) 365Z (Viet Nam) | | 323Z (China) 365Z (Viet Nam) | ||
|- | |- | ||
Line 479: | Line 528: | ||
| Fall 2003 | | Fall 2003 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | Analog - Motorola, EDACS, LTR | + | | Analog - '''Trunking: Motorola, EDACS, LTR''' |
| 315Z | | 315Z | ||
|- | |- | ||
Line 486: | Line 535: | ||
| 1999 | | 1999 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 493: | Line 542: | ||
| 1999 | | 1999 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 500: | Line 549: | ||
| 1999/2000 | | 1999/2000 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | Analog - Motorola, EDACS | + | | Analog - '''Trunking: Motorola, EDACS''' |
| | | | ||
|- | |- | ||
Line 507: | Line 556: | ||
| 1997 | | 1997 | ||
| style="color:red" | No | | style="color:red" | No | ||
− | | Analog - Motorola | + | | Analog - '''Trunking: Motorola''' |
| | | | ||
|- | |- | ||
Line 514: | Line 563: | ||
| 1995 | | 1995 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 521: | Line 570: | ||
| 1995? | | 1995? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 528: | Line 577: | ||
| 1994? | | 1994? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 535: | Line 584: | ||
| 1992? | | 1992? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 542: | Line 591: | ||
| 1988-? | | 1988-? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 549: | Line 598: | ||
| 1987-? | | 1987-? | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|- | |- | ||
Line 556: | Line 605: | ||
| 1981 | | 1981 | ||
| N/A | | N/A | ||
− | | No | + | | No Trunking |
| | | | ||
|} | |} | ||
Line 573: | Line 622: | ||
*[[Updating the Firmware in Uniden DMA Scanners]] | *[[Updating the Firmware in Uniden DMA Scanners]] | ||
*[[Uniden Scanners Systems, Sites and Groups]] | *[[Uniden Scanners Systems, Sites and Groups]] | ||
+ | *[[Uniden BCD996 Family]] | ||
==Programming== | ==Programming== |
Revision as of 09:43, 14 October 2020
Includes units made by predecessor Electra.
Specific questions on these scanners can be directed to the Uniden forum at Radioreference; be sure to look at the articles first. For software recommendations, USB cables, operating tricks and tips, see the appropriate section in the scanner's article or our Programming Your Uniden Scanner article. For information on reading the serial number, see the Uniden Scanner Serial Numbers article
See also Category:Uniden Scanners.
- Note
- The following convention should be used for specifying whether a trunktracker is Rebanding capable or not;
- YES - means that the scanner's firmware can be modified (or in the case of Home Patrol, data downloaded from the database) to support rebanding. Go to the Uniden TWiki Scanner Manuals Page for a comprehensive list of updates. Note that the XT models come rebanding-ready out of the box, but later firmware adds or fixes features.
- NO - means that the scanner's firmware cannot be modified to support rebanding
When adding a new article for this topic, please CATEGORIZE these pages by adding [[Category:Uniden Scanners]] as the last line
Contents
Base/Mobile Scanners
Radio Page | Image | Released | Rebanding | Trunk Tracking | Series |
---|---|---|---|---|---|
SDS200 | 2019 | Yes | Digital - Trunking:Motorola,EDACS,LTR, Digital:P25(Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN / Full US Database Load / GPS | 384Z | |
Beartracker 885 | 2018 | Yes | Digital - Trunking: Motorola,EDACS,LTR, Digital:P25(Phase 1+2) / GPS / CB - PreProgrammed for Police/Fire/EMS/DeptofTrans/Highway Patrol - Beartracker Warning System / Unable to program user freq. / Updated US Database weekly. | 378Z | |
BCD996P2 | 2015 03 | Yes | Digital - Trunking: Motorola,EDACS,LTR, Digital:P25(Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN / GPS | 378Z | |
BCD536HP | 2014 01 | Yes-Download from RRDB | Digital - Trunking:Motorola,EDACS,LTR,Digital: P25 (Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN - Full US Database Load / GPS | 375Z | |
HomePatrol-2 | 2014 11 | Yes-Download from RRDB | Digital - Trunking: Motorola, EDACS, LTR, Digital: P25 (Phase 1 and 2) - Full US Database Load / GPS | 377Z | |
BC-355N | 2012 | Yes-Download from RRDB | No Trunking Mobile - Service Search 25-54Mhz/108-174Mhz/406-512Mhz/806-956Mhz (no cell) | ||
HomePatrol-1 | 2010 11 | Yes-Download from RRDB | Digital- Trunking: Motorola, EDACS, LTR, Digital: P25 (Phase 1) / Full US Database Load / GPS | 363Z | |
BCT15X | 2009 08 | Yes | Analog - Trunking: Motorola, EDACS, LTR / GPS / SAME / 25-512Mhz/758-823Mhz/894-960Mhz/1240-1300Mhz | 361Z | |
BCD996XT | 2009 07 | Yes | Digital - Trunking:Motorola, EDACS, LTR, DigitalP25 (Phase 1) / GPS / 25,000 Channels /100ch sec scan / 25-512Mhz/758-823Mhz/849-868Mhz/894-960Mhz/1240-1300Mhz | 360Z | |
UBC800XLT | 2008 02 | N/A | Analog- Trunking: Motorola, EDACS, LTR Channels: 6,000 / GPS / 100ch sec scan / 25-512Mhz/806-960Mhz (no cell)/1240-1300Mhz. | ||
BC-RH96 | 2007 02 | N/A | Remote head for: BCD996T/BCD996XT/BCT15/BCT15X/BCD396T/BCD396XT/BR330T/BC346XT - will work with BCD996P2 with a converter. (Firmware req. for XT scanners) | 705Z | |
BCT15 | 2006 06 | Yes | Analog- Trunking: Motorola, EDACS, LTR / Channels: 2,500 / 100ch sec scan / 25-512Mhz/764-776Mhz/794-956Mhz (no cell)/1240-1300Mhz | 336Z | |
BC370CRS | 2006 06 | N/A | No Trunking-AM/FM Clock Radio / SAME - 25-54Mhz/108-174Mhz/225-512Mhz/806-956Mhz (no cell)/520-1720Khz(AM)/88-108Mhz(FM) | 338Z | |
BCD996T | 2006 05 | Yes | Digital- Trunking: Motorola, EDACS, LTR, Digital: P25 (Phase 1) Channels 25,000/ GPS / 25-512Mhz/758-823Mhz/849-868Mhz/894-960Mhz/1240-1300Mhz | 335Z | |
BC340CRS | 2006 04 | N/A | No Trunking- Clock Radio -Service Search / 100 Channel AM/FM/29-54Mhz/108-174Mhz/406-512Mhz/ | 337Z | |
BC898T | 2004 08 | Yes | Analog- Trunking: Motorola, EDACS, LTR - SAME / 25-54Mhz/108-174Mhz/216-512Mhz/806-956Mhz (no cell) | 322Z | |
BCT8 | 2004 02 | Yes | Analog- Trunking: Motorola, EDACS, LTR - Channels 250 / BearTracker Warning Sys / 25-54Mhz/108-174Mhz/400-512Mhz/806-956Mhz (no cell) | 318Z | |
BC350C | 2004 | N/A | No Trunking - Channels 100 user / 100ch sec scan / 25-54Mhz/108-174Mhz/406-512Mhz/806-956Mhz (no cell) | 317Z | |
BC796D | 2003 12 | Yes | Digital- Trunking:Motorola, EDACS, LTR, Digital: P25 (Phase 1) - SAME/Channels 1,000/ 25-512Mhz/849-868Mhz/894-956Mhz/1240-1300Mhz | 320Z | |
BC785D | 2003 02 | No | Analog- Trunking: Motorola, EDACS, LTR (w/BC25i card) Motorola Mixed mode 3600 baud- SAME/Channels 1,000/ 25-512Mhz/849-868Mhz/894-956Mhz/1240-1300Mhz | 316Z | |
BC780XLT | 2000 | No | Analog- Trunking: Motorola, EDACS, LTR - SAME / Channels 500 / 100ch sec scan/ 25-512Mhza/806-956Mhz (no cell)/1240-1300Mhz. | ||
BC278CLT | 1999 | No | No Trunking Clock Radio / SAME - 100 Channel - AM/FM/25-174Mhz/406-512Mhz/806-956Mhz (no cell) | ||
BC248CLT | 1999 | No | No Trunking Clock Radio / SAME - 50 Channel - AM/FM/29-54Mhz/137-174Mhz/406-512Mhz | ||
BC895XLT | 1997 09 | No | Analog- Trunking: Motorola I/II - Channels: 300 /Scan 100 Ch sec/ 29-54Mhz/108-174Mhz/216-512Mhz/806-956Mhz (no cell) | ||
BCT-12 StormTracker | 1997 | N/A | No Trunking Mobile/Pre-program for 50 States/ Bearcat Warning System/37-46Mhz/138-172Mhz/423-508Mhz/806-868Mhz | ||
BCT-12 | 1996 | N/A | No Trunking Mobile/Pre-program for 50 States/ Bearcat Warning System/37-46Mhz/138-172Mhz/423-508Mhz/806-868Mhz | ||
BC-760XLT | 1995 | N/A | No Trunking -100 Channel/Mobile/Pre-program / - 29-54Mhz/118-174Mhz/406-512Mhz/806-956Mhz | ||
BC-590XLT | 1995 | N/A | No Trunking -100 Channel /Mobile/Pre-Progrma/ 29-54Mhz/118-174Mhz/406-512Mhz | ||
BCT-10 | 1995 | N/A | No Trunking -Mobile/Pre-program for 50 States/ Bearcat Warning System/37-46Mhz/138-172Mhz/423-508Mhz | ||
BCT7 | 1994? | N/A | No Trunking - Mobile - BearTracker Alert System / 100 Channel CB/29-54Mhz/108-174Mhz/406-512Mhz/806-956Mhz | ||
BC-9000XLT | 1994 | N/A | No Trunking - 500 Channel / Alphanumeric - 25-54Mhz/108-174Mhz/216-512Mhz/806-956Mhz | ||
BC-148XLT | 1992 | N/A | No Trunking - 16 Channel / 2 Digit Display - 29-54Mhz/108-174Mhz/406-512Mhz | ||
BCT-2 | 1989 | N/A | No Trunking- Mobile -Pre-Programmed for 50 states / Beartracker Warning System - 29-54Mhz/118-174Mhz/406-512Mhz | ||
MR8100 | 1989? | N/A | No Trunking - 100 Channel - 29-54Mhz/118-174Mhz/406-512Mhz/806-956Mhz | ||
BCT-1 | 1987 | N/A | No Trunking -Mobile -Pre-Programmed for 50 states - 29-54Mhz/118-174Mhz/406-512Mhz | ||
BC-177XLT | 1987 | N/A | No Trunking - 16 Channel - 29-54Mhz/118-174Mhz/406-512Mhz | ||
Bearcat 210XLT | 1987 | N/A | No Trunking- 40 channels - 29-54Mhz/118-174Mhz/416-512Mhz. | ||
BC-175XL | 1986 | N/A | No Trunking - 16 Channel - 66-88Mhz/118-174Mhz/406-512Mhz | ||
BC-172XL | 1985 | N/A | No Trunking - 20 Channel - 29-54Mhz/108-174Mhz/406-512Mhz | ||
BC-140 | 1983 | N/A | No Trunking - Mobile - Channels - 10 Channel / 29-54Mhz/136-174Mhz/406-512Mhz | ||
BC-180 | 1982 | N/A | No Trunking - 16 Channel / 30-50Mhz/138-174Mhz/406-512Mhz | ||
BC-160 | 1982 | N/A | No Trunking - Channels - 16 Channel / 32-50Mhz/144-174Mhz/450-512Mhz | ||
BC350 | 1981 | N/A | No Trunking- Mobile - Channels - 50 user / 29-54Mhz/137-174Mhz/406-512Mhz | ||
BC300 | 1979 | N/A | No Trunking - 50 channels 30-50Mhz/108-136Mhz/144-174Mhz/420-512Mhz. | ||
Bearcat 210 | 1977 | N/A | No Trunking - 10 channels - 32-50Mhz/146-174Mhz/416-512Mhz. | ||
Bearcat 12 | ?? | N/A | Analog - Crystal - 10 Channel Vhf-Lo/Vhf-Hi/Uhf-lo/Uhf-hi 33-48Mhz/146-174Mhz/450-512Mhz. | ||
Bearcat 8-Track | ?? | N/A | Analog - Crystal - 4 Channel - VHF Hi/Lo 36-44Mhz/152-162Mhz (For autos with 8 Track Player). | ||
Bearcat 8 | ?? | N/A | Analog - Crystal - 8 Channel 33-48Mhz/146-174Mhz/450-512Mhz | ||
Bearcat 6 | ?? | N/A | Analog - Crystal - 6 Channel 30-48Mhz/146-174Mhz. | ||
Bearcat 5 | ?? | N/A | Analog - Crystal - 8 Channel 30-50Mhz/146-174Mhz/450-512Mhz. | ||
Bearcat Electra IV | 1974 | N/A | Analog - Crystal - 8 Channel - 30-50Mhz/146-174Mhz/450-512Mhz | ||
Bearcat Electra III | 1971 | N/A | Analog - Crystal - 8 Channel 30-54Mhz/146-174Mhz/450-512Mhz |
Handheld Scanners
Radio Page | Image | Released | Rebanding | Trunk Tracking | Series |
---|---|---|---|---|---|
SDS100 | 2018 | Yes | Digital - Motorola, EDACS, LTR, P25 (Phase 1+2),(with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN | 383Z | |
BCD325P2 | Apr 2015 | Yes | Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN | 379Z | |
BCD436HP | Jan 2014 | Yes-Download from RRDB | Digital - Motorola, EDACS, LTR, P25 (Phase 1+2), (with upgrades) EDACS ProVoice, Conventional DMR, MOTOTRBO (TM) Capacity Plus, Connect Plus, Linked Capacity Plus, Tier III, NXDN | 376Z | |
SR30C | 2019 | N/A | No Trunking | 385Z | |
BC75XLT | 2013 | N/A | No Trunking | 372Z | |
BC125AT | 2012 | N/A | No Trunking | 370Z | |
BC346XT | 2009 | Yes | Analog - Trunking: Motorola, EDACS, LTR | 358Z | |
BCD396XT | 2009 | Yes | Digital - Motorola, EDACS, LTR, P25 (Phase 1) | 359Z | |
UBC30XLT | 2006 | N/A | No Trunking | ||
BC95XLT | 2006 | N/A | No Trunking | 323Z | |
BCD396T | 2005 | Yes | Digital - Motorola, EDACS, LTR, P25 (Phase 1) | 328Z | |
BR330T | 2005-2007 | Yes | Analog - Trunking: Motorola, EDACS, LTR | 330Z | |
UBC3500XLT | ? | N/A | No Trunking | ||
BC92XLT | 2005 | N/A | No Trunking | ||
BC246T | 2004 | Yes | Analog - Trunking: Motorola, EDACS, LTR | 326Z | |
SC230 | 2004? | N/A | No Trunking | ||
BC296D | Early 2004 | Yes | Digital - Motorola, EDACS, LTR, P25 (Phase 1) | 319Z | |
BC72XLT | 2004 (China made) or 2011 (Viet Nam made) | N/A | No Trunking | 323Z (China) 365Z (Viet Nam) | |
BC250D & UBC300XLT |
Fall 2003 | No | Analog - Trunking: Motorola, EDACS, LTR | 315Z | |
SC200 | 1999 | N/A | No Trunking | ||
SC180 | 1999 | N/A | No Trunking | ||
BC245XLT | 1999/2000 | No | Analog - Trunking: Motorola, EDACS | ||
BC235XLT | 1997 | No | Analog - Trunking: Motorola | ||
BC3000XLT | 1995 | N/A | No Trunking | ||
BC80XLT | 1995? | N/A | No Trunking | ||
BC60XLT | 1994? | N/A | No Trunking | ||
SC150 | 1992? | N/A | No Trunking | ||
BC200XLT | 1988-? | N/A | No Trunking | ||
BC100XLT | 1987-? | N/A | No Trunking | ||
BC100 | 1981 | N/A | No Trunking |
Links
- Uniden Scanners
- Trunking Radio Comparison Chart
- Uniden Scanner Comparison
- Uniden Manuals
- Uniden Scanner eBay Listings
- Firmware updates
- Good selection of specs and images of Uniden equipment
- Form for requesting a scanner part that isn't listed on Uniden's main site.
- Common Trunking Programming Questions
- Uniden DMA FAQ
- Updating the Firmware in Uniden DMA Scanners
- Uniden Scanners Systems, Sites and Groups
- Uniden BCD996 Family
Programming
Conventional programming for most "older" Uniden scanners. Most scanners can be programmed in these five easy steps:
- Press Manual 1 Manual (should be channel 1)
- Enter a frequency
- Press E
- Press Manual to advance to the next channel
- Repeat steps 2 to 4
Conventional Programming XT/T Series of Scanners
- Press "Hold/Resume" Key While Scanning a Cnv System.
- From the Keypad input the Frequency directly ie "162.5500"
- Press "E/Yes" key
- Quick Freq Save?
- Press "E/Yes"
- This will save the conventional frequency to the "Qck Save Cnv System -> Qck Save Grp"
- If you desire to place the Cnv Freq. in a already existing conventional system press ".No" key, then select the Conventional system from the menu.