Actions

Difference between revisions of "BCD396T"

From The RadioReference Wiki

m
Line 63: Line 63:
 
* 12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, TV Broadcast, and Special (Itinerant)
 
* 12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, TV Broadcast, and Special (Itinerant)
 
* Custom Search — lets you program up to 10 search ranges
 
* Custom Search — lets you program up to 10 search ranges
* [http://info.uniden.com/twiki/bin/view/UnidenMan4/ToneOutMode Fire Tone Out] alert
+
* [[Fire Tone Out]] alert
** Also see the [[Fire Tone Out]] article 
 
 
* [[Channel Alert]]
 
* [[Channel Alert]]
 
* Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
 
* Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
Line 70: Line 69:
 
* [[SAME]] Weather Alert
 
* [[SAME]] Weather Alert
 
* Duplicate Channel Alert
 
* Duplicate Channel Alert
* [http://info.uniden.com/twiki/bin/view/UnidenMan4/PriorityScan Priority Scan] with Priority Plus
+
* [[Priority Scan]] with Priority Plus
 
** Also see the [[Priority Scan]] article
 
** Also see the [[Priority Scan]] article
 
* [[Signal Strength display]]
 
* [[Signal Strength display]]
Line 128: Line 127:
 
; External Links
 
; External Links
 
* [http://new.marksscanners.com/396/396.shtml Easier to Read BCD396T/UBCD396T Digital Scanner Manual]
 
* [http://new.marksscanners.com/396/396.shtml Easier to Read BCD396T/UBCD396T Digital Scanner Manual]
* [http://info.uniden.com/twiki/bin/view/UnidenMan4/ScannerManuals Uniden Manuals and Firmware Update Info]
 
 
* [http://my.uniden.com/downloads.cfm?product=BCD396T UASD Software, cable driver software and Firmware update link]
 
* [http://my.uniden.com/downloads.cfm?product=BCD396T UASD Software, cable driver software and Firmware update link]
 
* [http://www.uniden.info/download/ompdf/BCD396Tom.pdf BCD396T Owner's Manual]
 
* [http://www.uniden.info/download/ompdf/BCD396Tom.pdf BCD396T Owner's Manual]

Revision as of 05:35, 22 April 2021

LCD Close up
Bearcat BCD396T digital Trunktracker IV
3966.jpg
3 batteries
Belt Clip View


Uniden's APCO-25 Capable portable Trunktracker IV Scanner with Dynamic Memory Architecture.


Specifications

Limits

  • Channels: 6000 maximum
  • Systems: 400 maximum
  • Groups per system: 20 maximum
  • Talkgroups per trunked system: 200 maximum
  • Scan Rate: 100 channels per second (conventional mode)
  • System Quick Key range: 0-99
  • Group Quick Key range: 0-9
  • Custom Search Ranges: 10
  • Preprogrammed Service Search Bands: 12

Frequency Coverage

  • (North American Model BCD396T)
  • 25.0000 - 512.0000 MHz
  • 764.0000 - 775.9875 MHz
  • 794.0000 - 823.9875 MHz
  • 849.0125 - 868.9875 MHz
  • 894.0125 - 956.0000 MHz
  • 1240.0000 - 1300.0000 MHz
  • (Australia/New Zealand Model UBCD396T)
  • 25.0000 - 512.0000 MHz
  • 764.0000 - 775.9875 MHz
  • 794.0000 - 956.0000 MHz
  • 1240.0000 - 1300.0000 MHz

Power Requirements

Features

  • Can be updated to support Rebanding? YES
  • APCO25 Digital Audio decoding
  • Adaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systems
  • TrunkTracker IV with Motorola Control Channel Only trunking and I-Call monitoring
  • Uniden Close Call, with Close Call Do Not Disturb (with version 3 firmware), Close Call Priority (or Primary), and Close Call Temporary Store
  • 100 Quick Keys
  • Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel.
  • Supported step sizes: 5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHz
  • Adjustable (0-5 sec) scan delay
  • DCS/CTCSS Rapid Decode
  • Frequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked system
  • 16 character text tagging for each system, group, channel, talkgroup, search range, Tone-out, and SAME group
  • Compatible with BC-RH96 Remote Head
  • Analog and Digital AGC
  • Data Skip
  • Quick Search
  • Search with Scan for Service and Custom Searches
  • 12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, TV Broadcast, and Special (Itinerant)
  • Custom Search — lets you program up to 10 search ranges
  • Fire Tone Out alert
  • Channel Alert
  • Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
  • Weather Alert Priority
  • SAME Weather Alert
  • Duplicate Channel Alert
  • Priority Scan with Priority Plus
  • Signal Strength display
  • Blue LCD and Keypad Backlight
  • Battery level display
  • Battery saver
  • Key Lock
  • Adjustable Hold (scan duration 0-255 sec) per system, custom or service search
  • Strong signal attenuation
  • Upgradeable firmware
  • Repeater Reverse
  • Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc) with 10 custom bands
  • PC Programming and Control
  • Wired Cloning (Will only Clone to another BCD396T)
  • Antenna Connector: SMA (w/BNC adapter)
  • On-Air Cloning

RR System Compatibility

This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range:

  • System Types:
    • Motorola Type I
    • Motorola Type II
    • Motorola Type IIi Hybrid
    • Motorola Type II Smartnet
    • Motorola Type II Smartzone
    • Motorola Type II Smartzone Omnilink
    • Motorola Type II VOC
    • EDACS Standard (Wide)
    • EDACS Standard Networked
    • EDACS Narrowband (Narrow)
    • EDACS Narrowband Networked
    • EDACS SCAT
    • EDACS ESK (version 3.0 firmware or later required)
    • LTR Standard
    • Project 25 Standard
  • System Voices:
    • Analog
    • Analog and APCO-25 Common Air Interface
    • APCO-25 Common Air Interface Exclusive

Mods

Tips & Tricks

  • Frequency 'tune' mode: While in scanning mode, press HOLD, key in the frequency, then press HOLD. The scanner stays on this frequency. This also works for talkgroups (hit . twice for a dash). An error message is displayed if you enter a talkgroup while scanning a conventional system.

Reviews and User Opinions

eHam
UKMidlandscanner

Related Pages

External Links

, Firmware Upgrading

Wiki Articles

Supporting Software

ARC396 Version 2.0 Screenshot
Windows Software

Message Boards / Forums

RadioReference
Facebook
Groups.io
Twitter

BCD396T Scanners for Sale


Return to Uniden Scanners