Actions

Uniden Digital AGC Tweak Procedures

From The RadioReference Wiki

Revision as of 17:12, 20 March 2007 by Nonposter (talk | contribs)

Here is the procedure for tweaking the AGC digital/analog settings for the BCD396T and BCD996T.

NOTE! You MUST have digital AGC set to ON for the digital tweak to work. To adjust the analog AGC, Turn the digital AGC OFF, Make sure analog AGC is ON, then follow the same steps below, but be sure to remember to turn digital AGC back ON when finished. All settings are saved, even when you cycle power, and the option is no longer available until you access it again.

  1. Power on the 396T while pressing the HOLD/RESUME button.
    • Depending on model, you will hear two beeps OR the display will flash to indicate that the AGC tweak menu is enabled.
  2. Press in the function knob. WHILE THE F IS FLASHING IN THE UPPER LEFT OF THE DISPLAY, press the volume knob ONCE.
  3. The text "P25 RES TIME" appears in the bottom line of the display, with +0 next to it.
  4. Rotate the scroll knob to adjust the setting. -7 is the recommended setting (may vary per system)
  5. Once set to the desired level, press the scroll knob.
  6. Press the scroll knob again, and while the F is flashing, rotate the knob. P25 REF GAIN now appears, also with a +0 to the right of it.
  7. Rotate the scroll knob to adjust the setting. +3 is the recommended setting (may vary per system)
  8. Once set to the desired level, press the scroll knob.