Saskatchewan P25 and Trunktrackers
From The RadioReference Wiki
Revision as of 10:07, 29 April 2010 by Ka3jjz (talk | contribs) (→Update January 2010: Reports have come in from many Pro96 users stating that their scanners will not trunk this system at all.)
Revision as of 10:07, 29 April 2010 by Ka3jjz (talk | contribs) (→Update January 2010: Reports have come in from many Pro96 users stating that their scanners will not trunk this system at all.)
Contents
Trunktracker Information
- These M/A-COM P25ip Systems control channels use Multi-Block Messaging Operation for Explicit Group/Voice Channel Grants.
- All tower sites share the same system ID of HEX#00A/DEC#10 and the same WACN of HEX#0000A/DEC#10 and the same NAC of 10.
- These scanners will decode and trunktrack these systems, but older models may not;
The Radio Shack Pro-96/Pro-2096 can not decode the multi-block messages sent by the control channel so they may only trunk a single channel on a system. The BC250D and BC785D can not decode the 9600-baud rate control channel so it will not trunktrack these systems. The scanner must be able to operate in P25 9600 baud Explicit Mode.
Pro-96/2096 Trunking Information
- To trunktrack these systems the Pro-96/Pro-2096 must have custom extended tables programmed with Win96 software. These Radio Shack scanner models require a different set of custom trunking tables for every tower site in the system unless a site is used over again at another location in the Province. Channel #1 is 138.0150 and the last channel #100 is 139.5000. With this information the custom tables can be programmed for any tower site in the system.
- Tx Frequency Range 138-139.5000 MHz
- Rx Frequency Range 141-142.5000 MHz
- Base = 138.000 in all cases
- Step = 15.0 in all cases
Pro-96/2096 Custom Extended Tables
Site #001 Regina Downtown
Site | Name | Freqs | |||||
---|---|---|---|---|---|---|---|
10-005 (A-5) | Regina - SaskPower Head Office | 138.510000c | 138.675000c | 138.795000c | 139.035000c | 139.140000c | 139.245000c |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 34 | 00 |
01 | 35 | 45 | 35 |
02 | 46 | 53 | 46 |
03 | 54 | 69 | 54 |
04 | 70 | 76 | 70 |
05 | 77 | 83 | 77 |
Site #002 Pilot Butte
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-002 (A-2) | Alsask | 138.450000a | 138.555000a | 138.780000c | 139.275000a |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 35 | 00 |
01 | 36 | 58 | 36 |
02 | 59 | 66 | 59 |
Site #071 Fort Qu'Appelle
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-071 (A-47) | Fort Qu'Appelle | 138.240000a | 138.465000a | 139.095000c | 139.305000a |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 31 | 00 |
01 | 32 | 73 | 32 |
02 | 74 | 87 | 74 |
Site #081 Moose Jaw
Site | Name | Freqs | |||
---|---|---|---|---|---|
10-181 (A-B5) | Pasqua | 138.030000c | 138.210000c | 138.360000c | 138.720000c |
Slot Number | Low Channel | High Channel | Offset |
---|---|---|---|
00 | 00 | 02 | 00 |
01 | 03 | 14 | 03 |
02 | 15 | 24 | 15 |
03 | 25 | 56 | 25 |
04 | 57 | 64 | 57 |
Possible Firmware Issues
- It appears that version 1.4 firmware is unable to trunktrack this system. Version 1.3 firmware seems to be required until/if RS issues any further fixes (thanks VE5WIL)
Refresh this page from the latest database entry