Difference between revisions of "BCD996T"
From The RadioReference Wiki
m (→Related Pages) |
|||
Line 126: | Line 126: | ||
==Related Pages== | ==Related Pages== | ||
; External Links | ; External Links | ||
+ | * [http://marksscanners.com/996/996.shtml Easier to Read BCD996T/UBC996T Manual] | ||
* [http://info.uniden.com/twiki/bin/view/UnidenMan4/BCD996TFirmwareUpdate BCD996T Firmware updates] | * [http://info.uniden.com/twiki/bin/view/UnidenMan4/BCD996TFirmwareUpdate BCD996T Firmware updates] | ||
− | |||
* [http://www.uniden.com/pdf/BCD996Tom.pdf BCD996T User Manual] | * [http://www.uniden.com/pdf/BCD996Tom.pdf BCD996T User Manual] | ||
* [http://info.uniden.com/twiki/bin/view/UnidenMan4/BCD996TFirmwareUpdate#Revised_Protocol Control Codes for BCD996T] | * [http://info.uniden.com/twiki/bin/view/UnidenMan4/BCD996TFirmwareUpdate#Revised_Protocol Control Codes for BCD996T] |
Revision as of 16:43, 8 November 2009
Uniden's Base/Mobile Digital Trunktracker scanner with Dynamic Memory Architecture and GPS Support.
Started Shipping June 2006.
Contents
General Specifications
Power
- Voltage: 13.8 Volts d.c.
- Current: less than 750mA (max. rating of included wall wart)
- Power plug: 5.5mm outer diameter, 2.1mm inner diameter; Radio Shack size code "M"
Limits
- Channels: 6000 maximum
- Systems: 500 maximum
- Sites: 1000 maximum, 256 maximum per system
- Groups per system: 20 maximum
- Talkgroups per trunked system: 250 maximum
- Scan Rate: 100 channels per second (conventional mode)
- System Quick Key range: 0-99
- Group Quick Key range: 0-9
- Custom Search Ranges: 10
- Preprogrammed Service Search Bands: 13
Frequency Coverage
- 25 - 512 MHz
- 764 - 776 MHz
- 794 - 956 MHz
- 1240 - 1300 MHz
Features
- Rebanding Supported? YES See the Related pages section
- APCO25 Digital Audio decoding
- Adaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systems
- TrunkTracker IV with Control-Channel Only scanning and I-Call monitoring
- Close Call, with Close Call Do Not Disturb, Close Call Priority (or Primary), and Close Call Temporary Store.
- Fire Tone Out Alert
- Motorola Control Channel Only trunking
- DCS/CTCSS Rapid Decode
- Search with Scan
- Frequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked system
- 16 character text tagging for each system, site, group, channel, talkgroup, search range, GPS location, tone-out, and SAME group
- Compatible with BC-RH96 Remote Head
- Analog and Digital AGC
- Quick Search
- Service Search — lets you select from Public Safety, News, HAM Radio, Marine, Railroad, Air, Citizens Band Radio, FRS/GMRS, Racing, TV Broadcast, FM Broadcast, Military Air, and Special (Itinerant)
- Custom Search — lets you program up to 10 search ranges
- 500 (250 Temporary + 250 Permanent) Search Lockouts
- SAME Weather Alert
- Weather Priority
- Priority Scan with Priority Plus
- Signal Strength display
- Trunking Activity Indicators
- Adjustable (0-5 sec) scan delay
- Adjustable Hold (scan duration 0-255 sec) per system, custom or service search
- Strong signal attenuation
- Upgradeable firmware
- Channel Alert
- Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
- Repeater Reverse
- Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc)
- Quick Recall – quickly navigates to a specific Channel by choosing the System, Group, and Channel.
- Reversible Display - Lets you reverse the display to mount unit upside down (and hear the speaker from the top)
- DIN-E and ISO Vehicle Mountable
- Record Out — you can connect an output jack to a VOX controlled recorder or PC sound input to record the received audio.
- Duplicate Channel Alert
- Data Skip
- Key Lock
- PC Programming and Control
- Wired Cloning
- On-Air Programming
- Memory Back Up
- Physical Dimensions: Width 7.33 Height 2.21 Depth 5.94
- Power requirements: 11.0V to 16.6V DC
- Antenna Connector: BNC
RR System Compatibility
This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range:
- System Types:
- Motorola Type I
- Motorola Type II
- Motorola Type IIi Hybrid
- Motorola Type II Smartnet
- Motorola Type II Smartzone
- Motorola Type II Smartzone Omnilink
- EDACS Standard (Wide)
- EDACS Standard Networked
- EDACS Narrowband (Narrow)
- EDACS Narrowband Networked
- EDACS SCAT
- EDACS ESK (version 3.0 firmware or later required)
- LTR Standard
- Project 25 Standard
- System Voices:
- Analog
- Analog and APCO-25 Common Air Interface
- APCO-25 Common Air Interface Exclusive
Advanced Features
Uniden Multi-Site Trunking - allows independent system sites to share common talk group channel lists.
Location Based Scanning - If you connect a GPS unit to the scanner it can automatically enable/disable systems based on the geographic information you provide.
Startup Configuration - Pressing a number button while powering on the scanner automatically unlocks all systems assigned to that startup key and automatically locks all systems assigned to a different startup key (unassigned systems are not affected).
Temporary Lockout - Makes it easy to temporarily lock out a system, channel, or frequency. The lockout is cleared when you turn power off.
Six-Level Backlighting - Lets you set the display/keypad backlight to any of three brightness levels (or off) and two colors (red or green). Also lets you connect to your vehicle’s dimmer circuit to dim the scanner’s display with the vehicle’s dimmer control.
“Soft“ Search Keys - Let you program the keypad’s secondary functions to turn on/off specified search ranges.
Single-Handed Function Operation - Tap Function to access F+ key presses. 5 seconds after your last key press, the scanner reverts to non F+ entry (or press Function again to revert sooner).
Reviews
Related Pages
- External Links
- Easier to Read BCD996T/UBC996T Manual
- BCD996T Firmware updates
- BCD996T User Manual
- Control Codes for BCD996T
- Uniden USB-1 page on Scanner Master
- Wiki articles
- BCD996T QandA
- BCD996T Lat-Lon
- Uniden DMA FAQ
- Uniden Band Plan Entry Method (for V3 and later)
- DMA Radios Hints and Kinks
- JPEG of discriminator tap point
- Uniden scanner test modes
- Simulcast digital distortion
- P25_audio_decode_level_adjustment_(BCD396T)
- BCD996T AGC Tweak Procedure
- Digital End Code detection
- Software Support for Uniden Rebanding
- Compare the BCD996T to other digital models
PC Programming and Control
- BcTool
- BuTel Software products
- ARC996 Basic/Pro
- ARC996 PDF brochure
- ScannerStation
- Clone996 backup & restore utility (available from BCD996 or ARC996 Yahoo groups)
- FreeSCAN
- IDTracker II
- ProScan
- Scancat Lite Plus
- Scan Control
- Trunkstar Elite
- Trunkstar Elite Pro
- cat-streamer (Stream audio with site/group/channel tags)
- UASD Software** To Enter Registration Key: open program, click on "write to scanner", click on "setup" at top and then "registration" a box will open so that you can enter the number that was emailed to you ("demo" will now be removed from the write to scanner box)
- Firmware Updates
Yahoo Groups and Message Boards
- ARC996 Yahoo group
- BCTool Yahoo group
- BCD996T Yahoo group
- ProScan Support Forum
- Scan Control Yahoo group
- Scancat Yahoo group
- Strong Signals BCD996T forum
Talkgroup and Frequency display when scanning
Use display mode #2: Toggling the Display Mode To change the display so the channel and frequency or Talk Group ID appear instead of extended channel information, hold on any channel then press F + [0]. The scanner displays Display Mode 2. To return to Mode 1, press F + [0] Mode1 indicates the channel data under the Channel Name. Mode2 indicates the frequencies under the Channel Name for Conventional systems or the TGID number for Trunked systems.
eBay Listings
Return to Uniden Scanners