BCD325P2
From The RadioReference Wiki
The Uniden BCD325P2 is a APCO-25 Phase II capable handheld "Trunktracker V" scanner with Dynamic Memory Architecture. This scanner became available to the market in April, 2015. It is an upgrade and repackaging of the BCD396XT.
Contents
Specifications
Features
- TrunkTracker V -- Includes APCO P25 Phase I and II, Motorola, EDACS, and LTR
- 25,000 Channels
- Close Call™ RF Capture
- Temporary Lockout
- Location-Based Scanning
- Fire Tone-Out Alert
- Band Scope
- Rapid System/Channel Number Tagging
- DCS/CTCSS Rapid Decoding
- Audio AGC
- S.A.M.E. Weather Alert
- Location Alerts*
- Crows-Flight Navigation*
- Backlit LCD
- Dynamic Memory
- Custom Search
- 16 Character Text Tagging
- Narrowband Reception
- Key-Safe Mode
- IF Exchange
- Preemptive Trunking Priority
- 12 Service Searches: Public Safety, News, Ham Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast and Special (Itinerant)
- Multi-Site System Support
- Channel Volume Offset
- PC Programming and Control (with 3rd party software, not included)
In the Box
- BCD325P2 Radio Scanner
- Batteries (2 AA 2300mah)
- Flexible antenna (BNC)
- USB to USB Mini B cable(Programming/Charging)
- Hand strap
- Owner’s manual
- Belt Clip (Already attached w 2 screws)
Frequency Coverage
- 25.0000 - 512.0000 MHz
- 758.0000 - 823.9875 MHz
- 849.0125 - 868.9875 MHz
- 894.0125 - 960.0000 MHz
- 1240.0000 - 1300.0000 MHz
FM Bandwidths
- NFM: ~7.5 kHz deviation
- FM: ~15 kHz deviation
- FMB: ~75 kHz deviation
- WFM: >100 kHz deviation
Power Requirements
- Power requirements: 2 AA batteries(2.05v or higher) or 5V DC ≥300mA or AC adapter 5v ≥300ma.
RR System Compatibility
This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range:
- System Types:
- Motorola Type I
- Motorola Type II
- Motorola Type IIi Hybrid
- Motorola Type II Smartnet
- Motorola Type II SmartZone
- Motorola Type II SmartZone OmniLink
- Motorola Type II VOC
- EDACS Standard (Wide)
- EDACS Standard Networked
- EDACS Narrowband
- EDACS Narrowband Networked
- EDACS SCAT
- EDACS ESK (not ProVoice)
- LTR Standard
- Project 25 Standard
- Phase I (1) & Phase II (2)
- System Voices:
- Analog
- Analog and APCO-25 Common Air Interface
- Digital APCO-25 Common Air Interface Exclusive
Features
- Supports Rebanded Systems
- This scanner supports rebanding with firmware already installed. See the Updating the Firmware in Uniden DMA Scanners article for the firmware link
- APCO25 Digital Audio decoding
- NAC decoding
- Support for P25 Conventional channels that include NAC and TGID user differentiation (P25 One-Frequency Trunk)
- Adaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systems
- TrunkTracker V with Motorola Control Channel Only trunking and I-Call monitoring
- Multi-Site support
- Display UID (Unit IDs) on trunking systems.
- EDACS ESK support
- Standard Bearcat Orange back-lit display
- System / Channel Number Tagging - provides rapid access to a specific system or channel.
- Control Channel Data Output – allows the analysis of control channel data without the need to perform invasive modifications to the scanner. Now supported in UniTrunker version 1.0.0.10 or newer.
- Uniden Close Call, with Close Call Do Not Disturb, Close Call Priority (or Primary), and Close Call Temporary Store
- GPS Support for location-based scanning, location alerts, and crows-flight navigation
- [http://info.uniden.com/twiki/bin/view/UnidenMan4/LocationBasedScanning Independent GPS Control of Sites and Channel Groups
- 100 Quick Keys
- Supported step sizes: 5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHz
- Adjustable Band defaults
- Individual channel volume offset
- Intermediate Frequency Exchange - changes the IF used for a selected frequency to help avoid image and other mixer-product interference on a frequency.
- Key Safe Mode - lets you hand the scanner to a novice user and prevent programming from being modified.
- Private Systems - lets you flag a system so that it cannot be read out of the scanner or modified.
- Band Scope - gives a graphic representation of signal activity.
- Delay Channel adjustable to 0-2,5,10,30,
- Negative Channel dropout delay (forced resume) adjustable to -2, -5, -10 seconds
- DCS/CTCSS Rapid Decode
- Temporary System, Site, Group, Channel, and Location Lockout
- 500 (250 Temporary + 250 Permanent) Search Lockouts
- Startup Configuration
- Frequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked system
- 16 character text tagging for each system, site, group, channel, talkgroup, search range, location, Tone-out, and SAME group
- Analog and Digital AGC
- Ability to flag a channel as Digital, Analog, or All
- Quick Search
- Search with Scan for Service and Custom Searches with assigned Quick Keys
- 12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, Military Air, and Special (Itinerant)
- Custom Search — lets you program up to 10 search ranges
- 3 Quick-Access Search Keys
- Fire Tone Out alert
- Also see the Fire Tone Out article
- Fire Tone Out Search - built-in frequency counter displays the received tones.
- Channel Alert
- Independent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.
- Weather Alert Priority
- SAME Weather Alert
- Duplicate Channel Alert
- Priority Scan with Priority Plus
- Also see the Priority Scan article
- Adjustable Priority check interval
- Priority ID Scan on some trunked systems
- Preemptive Priority on Motorola analog systems
- Signal Strength display
- LCD Backlight
- Battery level display
- Battery saver
- Key Lock
- Adjustable Hold (scan duration 0-255 sec) per system, site, custom or service search
- Attenuation (for Strong signal -20db)
- Upgradeable firmware
- Repeater Reverse
- Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc) with 10 custom bands
- PC Programming and Control (No Uniden Software included or developed)
- Wired Cloning (Will only Clone to another BCD325P2)
- Antenna Connector: BNC adapter
Related Pages
- External Links
- Uniden BCD325P2 Wiki Page
- The required USB drivers can be found here
- Wiki Articles
Supporting Software
- See the Uniden DMA Software Support article for packages that support programming and virtual control
Message Boards / Groups
- RadioReference
- Yahoo! Groups
Return to Uniden Scanners